Electrical Connections  

Warning:   

Turn off power at the service box before wiring  

Duct Connections

  

Warning:  To reduce risk of fire, use only metal ductwork.

1. Power supply for 

the ventilator is 
115v AC 60HZ 

2. Remove top 

enclosure of the 
ventilator for 
access to the 
wiring terminal 
block. 

3. Push the electrical 

cable up through 
the bottom knock 
out of the external 
blower body.  Pull 
enough wire up 
into the housing to make attachment to the terminal block.  

4. Connect white to “NEUTRAL”, green to “GROUND” and the speed control wire to 

“HOT”.  

1. Use only round metal ducting, elbows and 

transitions or rectangular ducting having 
equivalent area of square inches as per 
required duct size. 

2. Tape all joints with UL 723 classified metal 

multi purpose duct tape. 

3. Turn on power and check ventilator operation  

4. Make sure damper opens and closes freely  

5. Install top enclosure of the ventilator. 