16
If the power supply cable is damaged, it shall be replaced with a cable
of the same type, with the cross-section of at least 3x0.75mm
2
.
Connecting central heating circulating pump
This operation shall be performed by a person with necessary
qualifications to perform electric installation works.
The circulating pump of the central heating installation shall be connected to the
socket (item
(4)
fig. 5) using a cable with cross-section of at least 3x0.75mm
2
.
The pump cable shall be terminated with the computer-type power supply plug
(item
(4)
fig. 4).
Connecting the hot water pump
This operation may be performed by a person with necessary
qualifications to perform electric installation works.
The pump, which charges the hot water reservoir shall be connected to the
socket (item
(3)
fig. 5), using a cable with cross-section of at least 3x0.75mm
2
.
Having finished with connections, the pump cable shall be terminated with the
computer-type power supply plug (item
(4)
fig. 4). The hot water reservoir
temperature sensor shall be connected to its input (item
(2)
fig. 5).
Connecting the room thermostat
This operation may be performed by a person with necessary
qualifications to perform electric installation works.
The room thermostat shall be connected to the socket (item
(1)
fig. 5)
by terminating the cable with the RCA plug (item
(3)
fig. 4) included with the
boiler. Operation of the controller when fitted with the local thermostat is
described in the PLUM ecoMAX 200 regulator instructions.
Unused outputs may be left unconnected.
Permissible output loads
Output
Output symbol
Current [A]
Central heating
pump
1
Hot water pump
1