Modentic Y-Type Installation, Operation & Maintenance Manual Download Page 2

 

 

 

 General:

 

1.  Strainers are devices for mechanically removing solids from flowing liquids or gases by 

means of a perforated or wire mesh straining element. They are used in pipelines to 
protect equipment such as pumps, meters, manual and control metal seated valves, 
steam traps and regulators. 

2.  Always use Modentic recommended spare parts for maintenance and replacement. 

3. Strainer 

Marking: 

All the marking information should be cast on the body, or on a metal plate which is 
spot-welded to the body.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PED VALVES MARKING 

MARK DESCRIPTION 

A TYPE 

NO. 

YEAR OF MANUFACTURE 

C MATERIAL 

D SIZE 

E PRESSURE 

 

F CE. 

MARK 

G TEMPERATURE 

TUV RHEINLAND 

/ BERLIN-BRANDENBURG 

HEAT NO. CAST ON THE BODY AND CAP   

MD LOGO CAST ON THE BODY OR   

ON THE NAMEPLATE 

 

X-XXX

                 

       

XXX

 

 

CF8M 

                 

DN32

 

 

PN40 

                                     

XXXXXXXX

 

0038 

PE

MARK DESCRIPTION 

D(SEP) VALVES MARKING UNDER DN25

 

A SIZE 

B MATERIAL 

C PRESSURE 

HE

LO

NA

AT NO. CAST ON THE BODY AND CAP MD 

GO CAST ON THE BODY OR ON THE 

MEPLATE 

 

 X

 

 C

 

 P

-XXX 

F8M 

N40 

Summary of Contents for Y-Type

Page 1: ...uld be installed at place where space for periodic inspection and maintenance is sufficient 5 Do not store or install the strainer near any heat source or hot surface The strainer may cause deformation destruction and fire 6 Avoid excessive force on the strainer when plumbed in 7 Essential safety working regulations are to be strictly kept 8 Do not disassembly when bearing pressure Strainer is not...

Page 2: ... All the marking information should be cast on the body or on a metal plate which is spot welded to the body PED VALVES MARKING MARK DESCRIPTION A TYPE NO B YEAR OF MANUFACTURE C MATERIAL D SIZE E PRESSURE F CE MARK G TEMPERATURE H TUV RHEINLAND BERLIN BRANDENBURG HEAT NO CAST ON THE BODY AND CAP MD LOGO CAST ON THE BODY OR ON THE NAMEPLATE X XXX XXX CF8M DN32 A PN40 XXXXXXXX 0038 B C E D F H G PE...

Page 3: ...are free from dirt and burrs And it might be necessary to flush the strainer and the pipes to remove the accumulated dirt and burrs 3 Always depressurize and drain the piping system before installation 4 Flanged Ends a Check companion of flanges are dimensionally compatible with the flanges on the valve body and make sure sealing surfaces are free of grease dirt etc b Prepare the suitable gasket f...

Page 4: ...stalled using standard piping practices 9 Always do leak test to the system before using Maintenance 1 Removal of screen a Check the piping system is completely depressurize and drained b Remove the drain plug on the end cap c Disassemble the coupling and end cap Be prepared to support the screen when removing the gasket and end cap d Rinse the screen to remove any debris that has accumulated 2 Sc...