background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

IEC 61850 Server / Modbus TCP Slave

 

 

Document code: MN67736_ENG     Revision 1.000   Page 25 of 25

 

 

 

WARRANTIES AND TECHNICAL SUPPORT: 
 

For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. 
Otherwise contact us at the address [email protected] 
 

 

RETURN POLICY: 
 

If while using your product you have any problem and you wish to exchange or repair it, please do the following: 

 

Obtain  a  Product  Return  Number  (PRN)  from  our  internet  support  at  www.adfweb.com.  Together  with  the  request,  you  need  to 

provide detailed information about the problem. 

 

Send  the  product  to  the  address  provided  with  the  PRN,  having  prepaid  the  shipping  costs  (shipment  costs  billed  to  us  will  not  be 
accepted). 

 
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no 
longer under warranty, you will receive a repair estimate. 

 

 

ADFweb.com S.r.l.

 

Via Strada Nuova, 17 

IT-31010 Mareno di Piave 

TREVISO (Italy) 

Phone +39.0438.30.91.31 

Fax +39.0438.49.20.99 

www.adfweb.com

 

Summary of Contents for HD67736-A1

Page 1: ...ACnet Slave www adfweb com Product HD67739 CAN www adfweb com Product HD67740 CANopen www adfweb com Product HD67741 DeviceNet Master www adfweb com Product HD67742 DeviceNet Slave www adfweb com Prod...

Page 2: ...D TECHNICAL SUPPORT 25 RETURN POLICY 25 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to t...

Page 3: ...The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and oper...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Modbus TCP Slave Document code MN67736_ENG Revision 1 000 Page 4 of 25 EXAMPLE OF CONNECTION...

Page 5: ...ustrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Modbus TCP Slave Document code MN67736_ENG Revision 1 000 Page 5 of 25 CONNECTION SCHEME Figure 1 Connection scheme for HD67736...

Page 6: ...ation between Ethernet Power Supply Two directional information between IEC 61850 bus and Modbus TCP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature...

Page 7: ...MN67736_ENG Revision 1 000 Page 7 of 25 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpt...

Page 8: ...ng on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is u...

Page 9: ...reen Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IEC 61850 communication green It blinks when a IEC 61850 request is received Blinks quickly Boot state Bl...

Page 10: ...converter must be made using Connector3 and or Connector4 of the HD67736 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T56...

Page 11: ...that runs with Windows called SW67736 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software prese...

Page 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC 61850 Server Modbus TCP Slave Converter in order to configure another device in th...

Page 13: ...ange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possi...

Page 14: ...0 Server Modbus TCP Slave Document code MN67736_ENG Revision 1 000 Page 14 of 25 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation ins...

Page 15: ...defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for IEC 61850 communication is defined If the...

Page 16: ...Address the IP address for Modbus TCP side of the converter is defined In the fields SubNet Mask the SubNet Mask for Modbus TCP side of the converter is defined In the fields Gateway the default gate...

Page 17: ...le is defined In the field Type the data format of the IEC 61850 variable is defined If the field Read Only is checked the IEC 61850 variable is just in reading Otherwise it is writeable too In the fi...

Page 18: ...own Certificate button from the Main Window of SW67736 Fig 2 the Definition the list of Known Certificates window appears Fig 5 The data of the columns have the following meanings If the field Enable...

Page 19: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put D...

Page 20: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to prog...

Page 21: ...of internal array Position Input Register 718 04 Input Bytes 1436 1437 of internal array Position Data in writing Type Address Function Description Holding Register 0 R 03 W 06 16 Output Bytes 0 1 of...

Page 22: ...Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Modbus TCP Slave Document code MN67736_ENG Revision 1 000 Page 22 of 25 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for...

Page 23: ...bination of the following HD67736 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67736 IEC 61850 Server Modbus TCP Slave Converter Order C...

Page 24: ...llection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 25: ...ease do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produ...