Modbus HD674-A003 User Manual Download Page 1

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

Modbus Slave / Modbus TCP Master - Converter 

 

Document code: MN674-A003_ENG     Revision 1.000  Page 1 of 30 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

User Manual 

Revision 1.000 
English 

 

Modbus Slave / Modbus TCP Master – 
Converter 

(Order Code: HD674-A003) 

 

For Website information:  

www.adfweb.com?Product=HD674-A003

    

  

 

For Price information: 

www.adfweb.com?Price=HD674-A003

      

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Wide supply input range 

 

Electrical isolation 

 

Industrial temperature range: 

 

-40°C / 105°C  (-40°F / 221°F) 

For others Gateways / Bridges:  

 
J1939 to Modbus

  

See also the following links: 

www.adfweb.com?Product=HD67212

 (Modbus RTU) 

 
CANopen to Modbus

  

See also the following links: 

www.adfweb.com?Product=HD67001

 (Modbus RTU Master) 

www.adfweb.com?Product=HD67002

 (Modbus RTU Slave) 

www.adfweb.com?Product=HD67004

  (Modbus TCP Master) 

www.adfweb.com?Product=HD67005

  (Modbus TCP Slave) 

 
For others Gateways / Bridges:  
For 

CAN bus 2.0A

 and/or 

CAN bus 2.0B

 to 

Modbus

 

See also the following links: 

www.adfweb.com?Product=HD67011

  (Modbus RTU Slave) 

www.adfweb.com?Product=HD67012

  (Modbus RTU Master) 

www.adfweb.com?Product=HD67014

  (Modbus TCP Slave) 

www.adfweb.com?Product=HD67015

  (Modbus TCP Master) 

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

User Manual   

 

Summary of Contents for HD674-A003

Page 1: ...s See also the following links www adfweb com Product HD67212 Modbus RTU CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67002...

Page 2: ...HNICAL SUPPORT 30 RETURN POLICY 30 Pagina 2 di 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Re...

Page 3: ...l interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the install...

Page 4: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 4 of 30...

Page 5: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 5 of 30 Figure 1a Connection sc...

Page 6: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 6 of 30 Figure 1b Conn...

Page 7: ...ned and also in both cases with Mini Fit connectors or AMP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof All the four series have these chara...

Page 8: ...age 8 of 30 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD674 A003 Exx xx 8V 26V 10V 40V Consumption...

Page 9: ...d in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Serial Communication green Blinks when Mod...

Page 10: ...S485 line with a 120 resistor in the HD674 A003 Exx xx is made internally of the device when the order is performed If the device have the RS485 terminated the code is the follow HD674 A003 Exx Yx oth...

Page 11: ...he T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended t...

Page 12: ...nverter use the available software that runs with Windows called SW674 A003 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to t...

Page 13: ...hich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable Modbus Slave Modbus TCP Master Converter in orde...

Page 14: ...tton there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sec...

Page 15: ...CP device is linked o Work with Fix IP Address the converter can be seen like a single serial Modbus slave The address of Modbus is assigned in the Set Communication section It is not necessary to com...

Page 16: ...default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the TCP port for Modbus TCP c...

Page 17: ...ndow Set Translate Table appears Fig 4 The data of the columns have the following meanings In the field Data Type the type of Modbus data is defined In the field Address the address of the Modbus regi...

Page 18: ...t Status address 110 Step 2 The Converter sends to the TCP Slave 192 168 0 19 the read request of Input Status address 100 Step 3 The slave TCP replies to the Converter with the data Step 4 The Conver...

Page 19: ...ce created by the converter is defined In the field IP Address TCP the IP address of the Modbus TCP slave device to which address the TCP requests is defined In the field Slave ID TCP the station ID o...

Page 20: ...from the serial slave Modbus ID 2 Step 2 The Converter sends to the TCP slave 192 168 0 19 the read write request using the TCP slave ID 1 Step 3 The slave TCP replies to the Converter with the data S...

Page 21: ...of frame to the slave with the IP address defined in the Set Communication section EXAMPLE 1 Using the configuration of Figure 3 Step 1 A serial Modbus master do the request to the Converter to read...

Page 22: ...Insert the IP 192 168 2 205 Press the Ping button Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload Whe...

Page 23: ...ssistance Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Op...

Page 24: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 24 of 30...

Page 25: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 2...

Page 26: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 2...

Page 27: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual Modbus Slave Modbus TCP Master Converter Document code MN674 A003_ENG Revision 1 000 Page 2...

Page 28: ...E y z s f Fixing lugs A Type A B Type B C Type C D without fixing lugs RS485 Termination Y Terminated with 120 N Not terminated Varnished Resinated V Varnished R Resined Connectors Type 4 MiniFit 7 Su...

Page 29: ...r European countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to a...

Page 30: ...you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed informa...