HORIZONTAL FILTER DUST COLLECTORS 

OPERATION & MAINTENANCE MANUAL

HORIZONTAL FILTER DUST COLLECTORS 

OPERATION & MAINTENANCE MANUAL

SUPERIOR PERFORMANCE

     And Quality In Blast Cleaning Equipment

www.modublast.com

Ph: (780) 425-5510

Fax: (780) 425-5540

  

 

  

!

WARNING

Manual #RPDC1810

Read Manual

Copyright© 2018 Mod-U-Blast®, All Rights Reserved

Failure to read, understand & 

follow all safety and operation 

procedures in this manual can 

cause injury or death. Manuals 

that are lost, incomplete, or 

damaged, must be replaced 

immediately.

For models M2000-4C, M3000-6C, M6000-12C, M9000-18C, M12000-24C

For models M2000-4C, M3000-6C, M6000-12C, M9000-18C, M12000-24C

Summary of Contents for M12000-24C

Page 1: ...425 5510 Fax 780 425 5540 WARNING Manual RPDC1810 Read Manual Copyright 2018 Mod U Blast All Rights Reserved Failure to read understand follow all safety and operation procedures in this manual can ca...

Page 2: ...ngs 4 Horizontal Filter Dust Collector Models 5 Operational Diagram 6 7 Important Safety Items 8 Dust Collector Start up and Operation 9 Magnehelic Gauge Operation 9 Dust Disposal 10 Dust Collector Ma...

Page 3: ...Production rates labour performance or surface finishes are the sole responsibility of the user based on the user s expertise experience and knowledge of industry variables It is the responsibility of...

Page 4: ...isconnect hoses while the system is under pressure this could cause serious injury or death WARNING Use proper respirator and eye protection when servicing the dust collector WARNING When servicing th...

Page 5: ...Copyright 2018 Mod U Blast All Rights Reserved Horizontal Filter Dust Collector Owner s Manual Horizontal Filter Models 5 M2000 4C M9000 18C M12000 24C M3000 6C With Silencer M3000 6C M6000 12C...

Page 6: ...er fan Dirty Air Inlet Operational Diagram Throughout normal operation the dust laden air enters the dust collector through the dirty air inlet plenum The dirty air flows downward towards the hopper a...

Page 7: ...ion Goyen valves open in sequence from top to bottom knocking dust out of the filters s the dust collector through the dirty air inlet plenum The dirty air flows he fine dust allowing clean filtered a...

Page 8: ...ection Hepa components When selecting a location for the dust collector take into consideration wind seismic zone and all load conditions Electrical installation service and maintenance must be perfor...

Page 9: ...Check the exhaust 5 Check the dust disposal The Magnehelic gauge measures differential pressure between the clean air and dirty air plenums of the dust collector and provides timely information of fil...

Page 10: ...lve is left open during operation of the dust collector it must be sealed to the waste container NOTE The auto pulse control panel uses a Zelio timer internally Should the pulse time between filter ba...

Page 11: ...k out before performing service or maintenance Turn off compressed air supply and bleed the dust collector storage tank before performing service or maintenance Start by removing the top row of filter...

Page 12: ...ove Most of the dust collectors will have 2 filters except the M2000 and the M3000 which are singles NOTE Dirty filters may be heavier than they appear Safe measures should be taken when removing When...

Page 13: ...O OF FILTERS STOCK NUMBER FILTER TYPE STOCK NUMBER DESCRIPTION STOCK NUMBER DESCRIPTION DC MODEL STOCK NUMBER M2000 4C 4 19123 Cartridge M3000 6C 6 19136 Cartridge M6000 12C 12 19123 Cartridge M9000 1...

Page 14: ...cessary See filter installation Access cover s loose Tighten door s Insufficient Airflow Blower fan rotation backwards Proper fan rotation is clockwise when looking down at the motor top Electrician w...

Page 15: ...abnormal use of the equipment or parts Parts considered consumables are not covered by warranty Claims will be honored only if the warranty card is returned within a period of two 2 months from the f...