3.2.3
PRESSURE
Parameter
Value
Range
300 hPa
–
1100 Hectopascals (hPa)
Offset temp. coefficient
±1.5 Pa/K
Table 3-4 Pressure Sensor Specifications
3.2.4
HUMIDITY
Parameter
Value
Range
0 - 100 %Relative Humidity (%RH)
Accuracy
± 3%
Table 3-5 Humidity Sensor Specifications
3.2.5
AMBIENT LIGHT
Parameter
Value
Range
0
–
64000 lux
Table 3-6 Ambient Light Sensor Specifications
3.2.6
DROP AND IMPACT
Parameter
Value
Range
1
–
25.5 G
Table 3-7 Drop and Impact Sensor Specifications
3.2.7
TILT
Parameter
Value
Range
0 - 180 (non-negative) Degrees
Table 3-8 Tilt Sensor Specifications