background image

1. 

Remove

 all the cable connection

s from the

 monitor before cleaning the 

device

.

2. Use a mild household detergent 

and c

lean the unit with a slightly damp

,

soft c

l

oth.

  

 Never use strong

 

solvents such as thinner or benzine

,

 as they might damage the finish

  

 of the 

device

.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

This symbol is intended to alert the user to the presence of uninsulated  "dangerous 
voltage"

 

within

 

the  product's  enclosure  that  may  be  of  sufficient  magnitude  to 

constitute risk of electric shock to persons.

This symbol is intended to alert the user to the presence of important operating and 
maintenance (servicing) instructions in the literature accompanying the appliance.

You are cautioned that any changes or modifications not expressly approved in this manual could 
void your warrantee and neccessitate expensive repairs.

CAUTION

This symbol is intended to alert the user not to waste electrical and electronic 
equipment.

  

Declaration of conformity

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions:
(1) This device may not cause harmful interference. 
(2) This device must accept any interference received, including      
      interference that may cause undesired operation.

2

Maintenance

Summary of Contents for M150-WL

Page 1: ...Operating Instructions Model M150 WL Please read this manual thoroughly before operating the device and keep it for future reference 2 4G 7 Inch Wireless Color LCD Monitor Digital V 1 2 ...

Page 2: ...atures 4 Accessories 5 Parts Identification 6 Remote Control Operation 7 Basic Operation 8 Menu 1 Picture 2 Option 3 System 9 Troubleshooting 13 3 Technical Specifications 11 9 8 6 5 9 4 3 3 1 12 Contents 4 Auto Scan 13 ...

Page 3: ...y our company or authorized dealer The monitor is a complex device Any disassembly or modification may lead to damage and void the warrantee Warning 1 Precautions Special Notice 1 Storage and Keeping 1 Do not expose the monitor to excessive heat or cold The storage temperature of this device is 30 80 and the operating temperature is 20 70 The humidity is RH90 2 Never use this device near a bathtub...

Page 4: ...e of sufficient magnitude to constitute risk of electric shock to persons This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance You are cautioned that any changes or modifications not expressly approved in this manual could void your warrantee and neccessitate expensive repairs CAUTION Th...

Page 5: ...k up left right or front camera views 2 Features 1 Product 7 Digital TFT LCD Color monitor with built in 2 4GHz wireless receiver 2 Resolution 800 x 3 RGB x 480 3 Contrast 500 1 4 Brightness 400cd m2 5 Viewing angle U 50 D 60 R L 70 6 Operation Frequency 2400 2483 5MHZ 7 Line of Sight Range 120M 8 Receiving Sensitivity 78dBm 9 Video Codec MPEG4 10 RF Band Width 5MHZ 11 Frame Rate PAL 25f s NTSC 30...

Page 6: ...4 4 Accessories Accessory supply may be different for different application U Support bracket Center mount bracket IR Remote control Angle adjustment screws Special Notice Power cable ...

Page 7: ...attaching piece Brightness increase Brightness decrease Setting selection down Remote control sensor Automatic brightness control sensor Digital Color LCD screen Power indicator Power switch Menu Loudspeaker Select CAM1 CAM2 CAM3 CAM4 ...

Page 8: ...r disassemble the remote control or allow it to drop or become wet 3 Press the control buttons firmly Allow 2 seconds for the picture to change Setting Selection Up Setting Selection Down Power Switch 6 Remote Control Operation Less Brightness More Brightness PAL AUTO NTSC Call Select CAM1 CAM2 CAM3 CAM4 ...

Page 9: ...HT Press to select the upper setting Press to select the lower setting or to display the scale Press to decrease Brightness Press to increase Brightness LANG Language Selection Press to select language display of English Deutsch Français Español Português Italiano Nederlands or Русский options SYS Press to select PAL AUTO NTSC Call Press to display video channel source SEL Press to select CAM chan...

Page 10: ...gle black wire to GND Single brown wire to positive power wire of back up light Single white wire to positive power wire of left light Single blue wire to positive power wire of right light Single green wire to any other trigger control Yellow RCA female for video output White RCA female for audio output DW 127D Brown Red Green White Black Blue Yellow RCA female White RCA female Video inputs Yello...

Page 11: ...ht turn light the monitor automatically switches to CAM2 right side camera when the right turn indicator is activated 7 3 1 When the white wire is connected to the positive wire of the left turn light the monitor automatically switches to CAM1 left side camera when the left turn indicator is activated 7 3 Reversing Display CAM1 CAM2 7 3 3 When the brown wire is connected to the positive wire of ba...

Page 12: ... on in dark environment OSD turns into dim mode for dim setting When auto dim is turned on off in bright environment OSD displays normal mode PICTURE DIM BRIGHT DIM CONTRAST DIM COLOR VOLUME AUTO DIM SCALE ADJUST 40 45 40 50 ON OFF Dim mode PICTURE AUTO DIM SCALE ADJUST BRIGHT CONTRAST COLOR VOLUME 50 50 50 ON OFF Normal mode 50 If is selected press to adjust the scale up down If is selected press...

Page 13: ...to choose the channel to be paired secondly press CH to select PAIRING Press to select ON OFF Scale refers to the reversing distance indicator displayed on the monitor Press CH to select SCALE OPTION SCALE PAIRING CAM1 CAM2 CAM3 CAM4 ON LANG ENGLISH OFF NORMAL NORMAL NORMAL NORMAL OPTION SCALE ON LANG ENGLISH OPTION SCALE ON LANG ENGLISH PAIRING CAM1 CAM2 CAM3 CAM4 OFF NORMAL NORMAL NORMAL NORMAL ...

Page 14: ...code matching doesn t complete in 50 seconds the screen will show PAIRING FAIL to tell you that code matching fails and you need to try again Other channels can be paired in the same way above 50 3 System COLOR SYS HORIZONTAL VERTICAL ZOOM functions will display on the screen as illustrated below Press CH to select COLOR SYS Press to select PAL AUTO NTSC SYSTEM COLOR SYS HORIZONTAL VERTICAL ZOOM S...

Page 15: ... loose The red wire from the monitor may be loose 9 Troubleshooting Use the remote control horizontal vertical selection switch to set proper orientation No picture no sound No picture No sound Dark picture Nocolor No reversing function i e Picture The symptoms described below do not necessarily mean a failure within the display Please check the following items before you initiate request for repa...

Page 16: ......

Reviews: