Figure 1 lists the requirements for the cables that 
connect to the camera.  Note that the camera has two 
options to receive power; only one should be used at a 
time. 

Table 1: Recommended power cable requirements 

PoE(802.3af): 

12VDC: 

Cat5, or better 

18 AWG, or larger 

Camera Description 

Figure 1: MVC-9000 Exterior Camera 

 

5

4

1

3

2

7

6

8

9

 

1. Cover 
2. Bubble 
3. IR 
4. Base 
5. Lens 
6. BNC Cable 
7. 12VDC Molex connector 
8. Ethernet RJ45 cable 
9. Reset Button 

Setting up the Camera 

To quickly put the camera into operation: 

1.   Prepare the mounting surface. 

2   Mount the camera using the appropriate fasteners. 

See the following “Mounting the Camera” section. 

3.  Set up the camera’s network and streaming 

parameters so that the camera can be controlled 
over the network. See section “Accessing the 
Camera over the Internet.”  For further information, 
please refer to the “MobileView 9000 & 9100 Series 
Analog/IP Camera User Manual”. 

4.   Program the camera to suit its location. For further 

information, please refer to the “MobileView 9000 & 
9100 Series Analog/IP Camera User Manual”. 

 

Mounting the Camera  

To Mount the Exterior Camera: 

1.   Use the supplied template to mark out the mounting 

area. Drill the screw holes on the surface.  Rivnuts 
with #8-32 machine screws (or larger) are 
recommended. 

 

2.  Loosen the cover screws, so cover can be removed.  

Secure the mounting base to the surface with 
appropriate screws.  

 

 

3.  Loosen the adjusting screw to adjust the pan, tilt and 

rotation angle, then re-tighten the adjusting screw

 

 

4.  Reinstall the cover screws. 

 

     

Accessing the Camera over 
the Internet 

Use the camera web browser to access and configure 
the camera over the internet (Microsoft Internet 
Explorer). Only one camera is accessible from a single 
web browser window. 

Summary of Contents for MobileView 9000 Series

Page 1: ...ion of the camera is well ventilated Temperature Do not operate the camera beyond the specified temperature humidity or power source ratings The operating temperature of the camera is between 30 to 65 C Servicing Do not attempt to repair this camera yourself Any attempt to dismantle this product except as required for normal installation will invalidate the warranty and may also result in injury R...

Page 2: ...lled over the network See section Accessing the Camera over the Internet For further information please refer to the MobileView 9000 9100 Series Analog IP Camera User Manual 4 Program the camera to suit its location For further information please refer to the MobileView 9000 9100 Series Analog IP Camera User Manual Mounting the Camera To Mount the Exterior Camera 1 Use the supplied template to mar...

Page 3: ...m Click to enable digital zoom Network and Streaming Configuration In the camera Web browser screen click the Configuration button on the toolbar to display the configuration screen See Figure 3 Figure 3 Configuration screen Refer to the MobileView 9000 9100 Series Analog IP Camera User Manual for detailed information on configuring the cameras See Table 2 for an overview of the configuration para...

Page 4: ...4 MobileView 9000 Series Exterior Analog IP Camera Quick Guide FCC Complicance Complies with FCC Part 15 Class A Contact information North America 855 MOBVIEW 662 8439 www interlogix com mobileview ...

Reviews: