![Mobeye ThermoGuard TwinLog CML2275 User Manual Download Page 16](http://html1.mh-extra.com/html/mobeye/thermoguard-twinlog-cml2275/thermoguard-twinlog-cml2275_user-manual_1814844016.webp)
15
5. CONFIGURATION
To program the Mobeye CML2275, the GSM module must have network connection.
In case only batteries are used, first switch the unit to the program mode. Next send
SMS commands for the configuration. All settings are stored and will be kept in the
unit, even in case the power supplies are removed.
5.1 PROGRAM MODE
If the unit is connected to an external power supply, the CML2275 has continuous
network connection and the unit is permanently in program mode.
If the unit is battery-powered the program mode can be achieved by pressing the
button for 5 seconds, until the LED starts flashing red and green. Alternatively, the
program mode can be accessed by (re) inserting the batteries.
First the GSM module establishes network connection. During this time the LED
flashes green/red. Normally this takes 10-30 seconds. Once the connection is
established the status LED starts flashing 1 sec. on/1 sec. off (or stays on continuously
in case the first telephone number has been configured).
In program mode, the device is ready to receive SMS commands. If no correct
command is received for 3 minutes, the GSM module switches off in order to save the
batteries. The unit returns to the low power operational mode.
The program mode is interrupted by pressing the button for one second until the LED
switches off. The unit is switched off completely (disarmed).