4 Configuration,
displays and connections
4.1 Configuration
The NMI can be fully controlled and configured with MOBA-NMS. In addition, it is pos-
sible to give out parameters through DHCP or SNMP.
More detailed information about the configuration with MOBA-NMS, DHCP and SNMP
can be found in the document BE-800793.
4.2 Reset
push-button
The NMI possesses a reset push-button between the two 2-pole clamps. To restart the
NMI (software reset), the push-button must be pressed for at least 4 seconds.
If the push-button is pressed for more than 20 seconds, the factory settings are loaded
(see chapter 9 Factory settings).
4.3
Connections and displays
The interface features the following connections and displays:
1
2
3
4
5
6
7
11
10
9
8
No. Group
Meaning and function
1
MOBALine out
MOBALine output signal, connection b
2
MOBALine output signal, connection a
3
DCF77 out current loop
negative connection ( - DCF out)
4
positive connection ( + DCF out)
5
Reset push-button
pressed for > 4 seconds, device restarts
pressed for > 20 seconds, device resets to factory settings
6
Alarm LED (red)
ON: at least 1 alarm active
7
Synch. LED (green)
ON: NTP synchronization OK
8
LAN socket (RJ45)
Ethernet connection
9
LAN activity LED (yellow) blinks: active network traffic
10
LAN link LED (green)
ON: Ethernet link OK
11
Power LED (green)
ON: PoE supply OK