5
Installation
5.1
Connections
The connections are specified in Appendix “A Connection diagrams“.
Only connect the designated devices to the various inputs and outputs.
5.2
Chassis Ground
In order to guarantee correct operation of the DTS 4210 the chassis must be
connected to an earth ground. The earth ground connection is specified in Appendix “A
Connection diagrams”.
5.3
Boot procedure of the DTS 4210.timecenter
The normal booting time of the DTS 4210 is approx. 180 sec. with pre-set IP or with
DHCP. The booting procedure of the operating system is displayed on the serial
console. After that, the text "starting" appears on the display (during the booting
procedure the display is dark and empty).
The display “starting“ remains until the time of output to the lines.
The duration, depending on the configuration, is 15-45 sec.
5.4
Initial configuration
Per default, all LAN interface for configuration (LAN1 – LAN3) are preconfigured with
DHCP on. After booting in a network with DHCP server, the received IP address can
be displayed.
If no DHCP server is available in the network, initial configuration has to be done via
serial terminal.
5.5
Firmware
It is recommended to install the current firmware on your device prior to the definite
commissioning. The current firmware can be found under
www.mobatime.com
Customer Data
Product Resources
Time Server
.
5.6
Basic settings (factory settings)