or
People are in the opening areas of the folding roofs.
After opening the transport lock, the roof flap opens automatically with
the aid of gas springs.
If necessary, push the wing into the end position by hand.
The profiles under the gas springs (tension / pressure protection) are
adjusted to the required length using a thread insert and locked in the
holding device on the main frame with ball lock pins.
Warnings:
The folding roofs open quickly and powerfully, do not stand in the
opening area!
All gas springs of the open roof flaps must always be supported by
additional safety devices (pull / pressure safety device).
Gas springs are filled with extremely high pressure - never hold or pull
on the gas springs!
When closing the folding roofs, make sure that the transport locks are
properly inserted.
Platforms / bottom flaps
Before opening the bottom flaps, make sure that there are no objects
or
People are in the opening areas of the platforms.
Carefully pull the platform into an approx. 45 degree position and align
the individual folding feet under the bottom flap.
Only then lower the bottom flap to the floor.
Adjust the height of the adjustable foot to the floor conditions by
screwing it in or out.
Depending on requirements and the conditions of the surface, the
adjustable feet are to be put under with plates.
Warning notice:
Before lowering the bottom flaps, always check that both pull type gas
springs are properly attached.
Gas springs are filled with extremely high pressure - never hold or pull
on the gas springs!
The gas springs must never be screwed on.
When closing the bottom flaps, make sure that all the folding feet are
folded in, otherwise the folding roofs will be damaged!
Opening the doors
Each door can be locked with an externally accessible lock cylinder.
Open the door slowly, making sure that there is enough play between
the underside of the door and
There is a bottom flap. All doors are equipped with a door opening
limiter which clicks into place when fully opened. A faint crack can be
heard.
The door is to be attached to the bottom flap frame with clamping
profiles.
Warning notice:
The doors must never be opened more than 90 degrees because
otherwise the gas springs of the bottom flaps and will be damaged.
Interior & electrical system
The floor of the interior consists of individual inlaid panels.
The electrical system of the modulbox is located in the ceiling area
under the surrounding perforated metal sheets.
Summary of Contents for modulbox
Page 3: ...bersicht modulbox MAX Aufstellvarianten overview MAX layouts...
Page 6: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 18: ......
Page 24: ...bersicht modulbox MAX mit Terrasse overview MAX double deck version...
Page 28: ......
Page 41: ...Hubsystem Sonderausstattung...
Page 42: ...Lichtdecke Variante Leuchtstoffr hren...
Page 43: ......