background image

10

30cm

180cm

50cm

50cm

Safety distances

-

The heater must be installed at a 

minimum height of 180 cm.

-

If installed in a toilet, the height should 

be 225 cm in zone 1 and zone 2; in zone 

3 the minimum above ground level is 

180 cm, according with the rules of each 

Country.

-

A minimum air gap of 30 cm should 

always be allowed between the top of 

the heater and a ceiling or roof. The 

appliance should be 50 cm far from the 

walls

Summary of Contents for HOT-TOP Extra Large

Page 1: ...1 Longwave infrared heater Classe 1 IP55 MANUALE D USO E MANUTENZIONE EMPLOI ET ENTRETIEN USE AND MANTAINANCE GEBRAUCH UND WARTUNG USO Y MANTENIMIENTO USO E MANUTENÇÃO DICITURA IN ARABO ...

Page 2: ...u can use it as long as you like since its warmth is invisible You won t see any luminous ray but it functions like the sun warming the bodies instead the air For this reason there is no need to warm up the complete environment for feeling good It is perfect for restaurants offices supermarkets factories and patios It emits no light on but as the sun radiating bodies without heating the air dedica...

Page 3: ...ion from the rear side It is also for this reason that the minimum distance from the wall or the ceiling is shorter The top quality material and strongest surface casting make it more resistant than ever Weather and use won t damage it The tubular resistances on duct have been volcanized with silicon in order to make them lasting longer and longer Design engineering and production made in Italy De...

Page 4: ...maintenance must be performed by the user and not by unsupervised children 4 Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use...

Page 5: ... gas inflammable or explosive liquids or substances Defined in BS5345 7 Some fundamental rules which apply to all electrical devices must be observed when using the heater Do not touch the heather with wet hands Do not handle with bare feet Do not let children play with the electrical appliance 8 Do not apply any modification to the product 9 Keep connections dry 10 Ifthepowersupplycordisdamaged a...

Page 6: ...6 Model and warmth diffusion POWER 1500W RADIATE AREA 3150cm RANGE 5 m WEIGHT 5 7kg Small Medium POWER 1800W RADIATE AREA 3650cm RANGE 7 m WEIGHT 6 4kg 2 5m 1 8m 2m 1 25m 1 1m 2m 1 6m 2m 95mm 202mm 58mm ...

Page 7: ...7 POWER 2400W RADIATE AREA 4575cm RANGE 9 m WEIGHT 7 8kg Large POWER 3200W RADIATE AREA 5850cm RANGE 12 m WEIGHT 9 8kg Extra Large 1 55m 3m 2m 2m 1 95m 4m 3m 2m Temperature increase 16 5 10 ...

Page 8: ...olarities Connecting the machine the blue LED lights flashing Use the remote control as shown in figure For maximum flexibility all models are available with dimmer to adjust the intensity of the heater comfortably by remote control The length of each model increases by 15 cm while the width and height remain unchanged ...

Page 9: ...OWER HIGH select max power the red LED lights on MED select 2 3 of power the violet LED lights on LOW select 1 3 of power the blue LED lights on OFF shutdown device ON ignition device which leads LOW power ...

Page 10: ...lled in a toilet the height should be 225 cm in zone 1 and zone 2 in zone 3 the minimum above ground level is 180 cm according with the rules of each Country A minimum air gap of 30 cm should always be allowed between the top of the heater and a ceiling or roof The appliance should be 50 cm far from the walls ...

Page 11: ...the ceiling You must leave enough space around the top of the unit to ensure good ventilation Do not use the heater in close proximity of a bath shower or swimming pool If there is nobody in the room to be heated it is recommended to turn off the unit Wait 15 20 minutes after power to reach the maximum temperature ...

Page 12: ...12 The support to be fixed to the wall presents a series of holes that allow to fix the heater in different positions cod 004456 Provided wall ceiling support ...

Page 13: ...13 End to end cod 7705 Twin cod 7704 Extension cod 7706 Optional supports ...

Page 14: ...Ensure that the wall where you intend to attach the device is solid and that within it do not pass electric cables or water pipes 9 6cm recommended value Small 80cm Medium 95cm Large 125cm Extra Large 180cm 1 Drill four holes in the wall as shown below 2 Fix the two supports to the wall using dowels of appropriate size ...

Page 15: ...rail on the upper side of the device 4 Align the holes of the supports and join them together using the supplied bolts setting the desired inclination Ensure that the heater turns her rays in the area to be heated Firmly tighten the screws when finished ...

Page 16: ...ter must always be properly earthed The appliance must be connected to energy supply line by means of the provided H05SS F silicone cable An overvoltage category III Combined Circuit breaker and Residual Current Device RCD with rated earth leakage operation not exceeding 30mA must be fitted upstream on the supply line The circuit breaker must have a contact opening distance of at least 3 mm The pr...

Page 17: ...ust be installed so as to prevent that the switches can be touched from those who are in the shower Avoid the use of an extension cord with this product because the extension cord may overheat and cause a risk of fire Ensure that there is no possibility of inflammable material combustible material or curtains coming into contact with the heater or lie near the heater Additional information Active ...

Page 18: ... your appliance call the local authorized distributor or the nearest Service Centre Every repairs should be carried on by an authorized Service Centre and also ask always for original spare parts Technical service Care and cleaning Beforecleaning besuretheapplianceisdisconnected from the power supply and allowed to cool Never immerse the appliance in water or any other liquid Always disconnect the...

Page 19: ...r more detailed information regarding the collection systems available contact your local waste disposal service or the shop where you purchased the product Producers and importers comply with their responsibility for the recycling treatment environmentally friendly disposal either directly or by participating in a collective system Disposal This product conforms to EU Directive 2002 96 EC This ap...

Page 20: ...20 Mo El S r l Via Galvani 18 42027 Montecchio Emilia RE ITALY Tel 39 0522 868011 Fax 39 0522 864223 info mo el com www mo el com ...