MM Kembla KemPress KPSA Design & Installation Manual Download Page 5

Key Features

• 

Safe handling with slip-proof rubberised housing

• 

Signals if press not completed correctly - Immediately  

  after the pressing cycle a green lights shows if the required   
  pressing force was achieved, a red light if not

•   

Automatic press cycle. Once it starts, it will automatically 
complete. (manual override)  

 

• 

Electronic log book allows for quick and precise    

  analysis of errors for servicing and repair

• 

Electronic monitoring of the jaw locking  

  bolt and visual error indicator (KPL)

•   

When you reach the maximum number of presses  
before a service is required a warning light flashes.  
The machine will not close down enabling you to  
complete the job in hand. 

• 

Redundant switch-off

• 

Rotatable head (KPSA) 

 

Tool Operation

Holding the tool securely, press and hold the start button for 
2 seconds to begin the automatic press cycle (the green LED 
will go out). Release the start button and continue to hold the 
tool securely. The green LED will light when the press cycle is 
complete. To cancel the automatic press cycle press and hold 
the release button on the side of the tool until the tool turns off. 
If the red LED lights up, press the start button. If the tool does 
not run, call Kembla Hong Kong for advice. If the red and 
green LEDs flash alternately, the tool is ready for a service, 
contact Kembla Hong Kong Customer Service Centre.
The tool will turn off automatically after 30 minutes of no use. 
Turn the tool ON by quickly pressing and releasing the start 
button and open the jaws around the fitting. 

Tool Maintenance

Carry out basic inspection of the pressing device and jaws prior 
to each use to ensure they are clean and free from debris and 
dirt. The pressing jaws should be visually inspected to ensure 
there are no cracks. If there are any cracks in the pressing jaws, 
do not use them, as there is risk of the jaws shattering and 
potential injury from flying fragments. It is recommended to 
always wear appropriate eye protection whenever using the 
pressing device.  When inspecting the pressing jaws, also ensure 
that there are no foreign material deposits and that the contours 
of the jaw surfaces are in order. Failure to do this may result in 
damage to the jaws and/or the pressing device. Always remove the 
battery before performing regular cleaning and maintenance work.
The pressing device, jaws and batteries must be serviced at 
least within 40,000 presses. Failure to have the required services 
carried out may affect the warranty.

Tool Service Program

The Kembla Hong Kong tool service and repair program 
is easy, ensures minimal down time and provides known 
maximum costs for repairs. The key components of the 
program include:

•   

Replacement tools available while your tool is being 
serviced/repaired

•   

Maximum repair price guarantee: the cost won’t exceed  
our maximum repair price and if the cost of repair is less,  
you only get charged that amount

•   

No fix, no charge

•   

Up to 12 months warranty on repairs 

Any service or repair of the KemPress

®

 pressing tool or jaws, 

requiring opening the device, or mechanical repairs, shall only 
be carried out by MM Kembla or their authorised agent.  
Failure to do so may void the warranty.

11

®

Reviews: