background image

 

 

 

 

 

 

 

 

 

 

Fig. 4 

 

Secure the cable with the cord grip provided 

 

Close the terminal cover and fasten with the screws provided 

 

Plug the RCD plug into a socket outlet, switch on and check for correct operation. See below for 

operation of the RCD 

For security, and to prevent unwanted tampering with the socket outlet, a lug feature with a 6mm hole is 

provided to accept a padlock or similar locking security device (not included). 

Note: The power indicator is lit when there is power to the unit and the switch is on, irrespective of whether a 

load is plugged in or not. 

RCD TEST PROCEDURE 

When the RCD is first plugged in, press the green RESET button to switch on the supply to the socket. The red 

indicator should appear. 

To test that the RCD is operating correctly, press the blue TEST button. The red indicator should turn black and 

power to the socket should be disconnected. 

To restore power, press the green RESET button. The red indicator should reappear. 

If the RCD should trip due to a fault, the RESET button can be pressed after the fault is rectified. If the RCD will 

not reset, remove any connected loads from the socket outlet and check for water ingress or damage.  

Following a power cut the RCD will automatically reset itself and does not need manually resetting. Care should 

be taken to avoid connected loads powering up without warning. 

The TEST button should be pressed at regular intervals to check that the RCD is functioning correctly. We 

recommend testing every 3 months. If the red indicator does not turn black when the TEST button is pressed, 

do not use.  

The RCD plug is fitted with a 13A fuse to BS1362. To replace the fuse, gently prise open the fuse carrier with a 

small flat-bladed screwdriver. 

WARNING 

To ensure continued safe and proper weatherproof operation, the unit must not be left with the cover raised 

open or the catch left unlocked. 

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed.

 

GENERAL 

This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities 

for where facilities exist.  

Reviews: