INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following product: 

EMTWIN 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is for indoor use only 

 

This product is Class I and must be earthed 

 

This product is IP20 

INSTALLATION 

 

Provide power to the required point of installation  

 

Open the front cover by unfastening the two screws (see Fig. 1) 

 

Fig. 1 

 

Mark the location for, and drill the fixing holes ensuring not to infringe with any gas/water pipes or 

electrical cables  

 

Carefully remove one of the 20mm knockouts on either side of the fitting, and fit a suitable grommet or 

gland (not included) 

 

Feed the mains cable into the luminaire and fix to the surface using appropriate fixings (not included) 

 

Connect the luminaire to the mains supply ensuring the correct polarity is observed: L - Live (brown), E 

- Earth (green/yellow), N - Neutral (blue)  

 

Connect the battery to the battery connector on the PCB 

 

Replace the front cover 

 

Switch on and check for correct operation, ensuring the CHARGE and LAMPS HEALTHY indicator 

LEDs are illuminated 

 

We recommend, on commissioning the installation, a minimum charge period of 24 hours before 

carrying out an emergency duration test 

 

If the batteries have been left in a discharged state for an extended period, we recommend that one or 

more charge and discharge cycles are completed which should help to restore the battery capacity  

WARNING 

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 

testing. Irreparable damage will occur if this instruction is not followed. 

GENERAL 

Fig. 1

• Mark the location for, and drill the fixing holes ensuring not to infringe with any gas/water pipes or electrical 

cables 

• Carefully remove one of the 20mm knockouts on either side of the fitting, and fit a suitable grommet or gland 

(not included)

• Feed the mains cable into the luminaire and fix to the surface using appropriate fixings (not included)
• Connect the luminaire to the mains supply ensuring the correct polarity is observed: L - Live (brown),  

E - Earth (green/yellow), N - Neutral (blue) 

• Connect the battery to the battery connector on the PCB
• Replace the front cover
• Switch on and check for correct operation, ensuring the CHARGE and LAMPS HEALTHY indicator LEDs are 

illuminated

• We recommend, on commissioning the installation, a minimum charge period of 24 hours before carrying 

out an emergency duration test

• If the batteries have been left in a discharged state for an extended period, we recommend that one or more 

charge and discharge cycles are completed which should help to restore the battery capacity 

Summary of Contents for EMTWIN

Page 1: ...INSTALLATION MAINTENANCE MANUAL EMTWIN ...

Page 2: ...y doubt consult a qualified electrician Please isolate mains prior to installation or maintenance Check the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this product when deciding the location for installation This product is for indoor use only This product ...

Page 3: ...ted which should help to restore the battery capacity WARNING This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing Irreparable damage will occur if this instruction is not followed GENERAL Fig 1 Mark the location for and drill the fixing holes ensuring not to infringe with any gas water pipes or electrical cables Carefully remove one ...

Page 4: ...ed from the circuit if subjected to any high voltage or insulation resistance testing Irreparable damage will occur if this instruction is not followed The light source of this luminaire is not replaceable when the light source reaches its end of life the whole luminaire should be replaced Clean with a soft dry cloth only do not use aggressive cleaning products or solvents which may damage the pro...

Page 5: ...230V 50Hz IP20 Class 1 Non Dim house Ta 0 45 D ...

Page 6: ...ey switch or switching off circuit breaker Ensure normal supply is restored after test and ensure charge indicator is illuminated Annual three hour duration test simulate a mains supply failure for three hour continuous test by operation of key switch or switching off circuit breaker Ensure normal supply is restored after test and ensure charge indicator is illuminated If the luminaire fails any o...

Reviews: