INSTALLATION
• Provide power to the required point of installation (refer to BS7671 for correct cabling
methods)
• The power source connections should be local and accessible via a suitable IP rated
enclosure
• The pre-installed cable supplied is for above-ground use only. Cables that are to be
routed within walls or below ground must be protected by means of suitable conduit or
trunking
• Connect the driver to the mains supply ensuring the correct polarity is observed:
L - Live (brown), E - Earth (green/yellow), N - Neutral (blue) (see Fig. 1)
• Connect a suitable LED load to the secondary side of the driver: + (red/brown),
-(black/blue)
• Switch on and check for correct operation
Fig. 1