![MKS Newport IDL225-1200LM User Manual Download Page 17](http://html1.mh-extra.com/html/mks/newport-idl225-1200lm/newport-idl225-1200lm_user-manual_1813433017.webp)
7
IDL225-LM Series
Long Travel Industrial Linear Stages
4.3
Sensor Positions
4.4
Position Feedback Signals
– End-of-Run Limit
+ End-of-Run Limit
Index Pulse
Index Pulse
Motion
Dir
Direction –
1.97
(50)
.08 (2)
.08 (2)
Negative
Software Limit
Stage Travel Range
Positive
Software Limit
Home Position
(Origin)
Dimensions in inches
(and millimeters)
X
Dir
X Values
– Hard
– End-of-Run
Home
+ End-of-Run
+ Hard
[in. (mm)]
Stop
Limit
Position
Limit
Stop
IDL225-300LM
7.40
0
-0.35
7.52
±0.02
13.50
±0.04
19.49
±0.02
19.61
+0.35
0
(188
0
-9
)
(191
±0.5
)
(343
±1
)
(495
±0.5
)
(498
+9
0
)
IDL225-400LM
7.40
0
-0.35
7.52
±0.02
15.47
±0.04
23.43
±0.02
23.54
+0.35
0
(188
0
-9
)
(191
±0.5
)
(393
±1
)
(595
±0.5
)
(598
+9
0
)
IDL225-600LM
7.72
0
-0.35
7.83
±0.02
19.72
±0.04
31.61
±0.02
31.73
+0.35
0
(196
0
-9
)
(199
±0.5
)
(501
±1
)
(803
±0.5
)
(806
+9
0
)
IDL225-1200LM
7.72
0
-0.35
7.83
±0.02
31.54
±0.04
55.24
±0.02
55.35
+0.35
0
(196
0
-9
)
(199
±0.5
)
(801
±1
)
(1403
±0.5
)
(1406
+9
0
)
Signal description/Voltage/Wiring
Heidenhain standard 1 Vpp
Reference mark position
see drawing "Sensor Positions"
Resolution
Scale pitch 20 µm
Maximum speed
8 m/s
Low
High
Low
High
Low
High
Low
High
Encoder
Phase A
Encoder
Phase A
Encoder
Phase B
Encoder
Phase B
1
2
3
4
Encoder Feedback Signal Position
Motion
Dir
Direction –
Dir
A104
4F
0 - EDH036
1
En
10
5
0
—
0
2/
20