Service manual
Continuation rewiring and reprogramming the reserve relay
Terminal
connection on
gas- and
communicatio
n pcb
Contact
type
Protected by
/
potential-
free
Actor name
Actor Comments / rewiring instructions
X4.1
Input
230V input
X4.2
N. O.
Gas Reset 1
K22
Rewire cable from X4.2 to X9.9 and
assign reserve relay.
X4.3
N. O.
Gas Reset 2
K21
Rewire cable from X4.3 to X9.9 and
assign reserve relay.
X4.4
N. O.
Gas „On“ 1
K14
Rewire cable from X4.4 to X9.9 and
assign reserve relay.
X4.9
N. O.
Gas „On“ 2
K15
Rewire cable from X4.9 to X9.9 and
assign reserve relay.
N. C. = normally closed contact
N. O. = Normally open contact
Reorganisation and reprogramming into the default situation
To „charge“ the reserve relay not unnecessary,an exchange of the control board to the default situation
should be established again.
Procedure
➢
Establish original state of the wiring (from X9.9 back to X ... ) .
➢
Select
ReL
(relay test) in the service menu..
➢
Select relay K17 and push the
FLEXI-button
.
After the reserve relay was assigned with the
FLEXI-button
, the
FLEXI-LED
must be on.
➢
Leaving the relay test by pressing the
STEP-button
.
➢
Press the
FLEXI-button
to save changes.
StO
(Store) appears on the upper display.
➢
Leaving service menu by pressing the
STEP-button
.
57