Install The Equipment: 

 

When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without 

any deformation. When installing the unit must be secured with a secondary safety attachment, e.g. and 

appropriate safety cable. Never stand directly below the unit when mounting, removing, or servicing the unit. 

 

Overhead mounting requires extensive experience, including calculating working load limits, installation 

material being used, and perodic safety inspection of all installation material and unit. If you lack these 

qualifications, do not attempt the installation yourself.

 

The installation should be checked by a skilled person once a year. 

 

 

The Inno Pocket Zoom 4 is fully operational in three different mounting positions, hanging upside-down from 

a ceiling, set on a flat level surface, or on its side attached to trussing. Be sure this fixture is kept at least 0.5m 

away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a 

safety measure to prevent accidental damage and/or injury in the event the clamp fails (see next page). 

 

NOTICE: 

The suitable enviromental temperature for this lighting fixture is between -

25˚ C to 45˚ C. Do not place 

this lighting fixture in an enviroment where the temperatures are under or above the temperatures stated above. 

This will allow the fixture to run at its best and help prolong the fixture life. 

 

Summary of Contents for Inno Pocket Zoom 4

Page 1: ...MJ 1038 INSTRUCTION MANUAL PROFESSIONAL LED LIGHTING Thank you for choosing our LED mini zoom moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries on the product improvement about our company th...

Page 3: ...ch the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by th...

Page 4: ...urself The installation should be checked by a skilled person once a year The Inno Pocket Zoom 4 is fully operational in three different mounting positions hanging upside down from a ceiling set on a flat level surface or on its side attached to trussing Be sure this fixture is kept at least 0 5m away from any flammable materials decoration etc Always use and install the supplied safety cable as a...

Page 5: ...al Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers...

Page 6: ...e to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR ...

Page 7: ... DMX line When inserting standard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion System Menu DMX 512 Address setting Channel Mode 10 12 15Channel mode Master Slave Mode NAST master mode SL1 SL2 slave mode Show Mode Auto Mode Sound Mode ...

Page 8: ... set Menu test Auto Test Rest Mode System Menu When making MJ adjustments press ENTER to confirm your setup then press and hold the MENU button for at least 5 seconds To exit without making any adjustments press the MENU button The display will lock after 30 seconds press the MENU button for 3 seconds to unlock ...

Page 9: ...tton until SHND is displayed press ENTER 2 Sh X will now be displayed X representing a number between 0 4 Shows 1 4 are factory programs while show 0 is random mode Use the UP or DOWN buttons to find your desired show 3 When you have found your desired show press ENTER then press and hold the MENU button for at least 3 seconds to activate After you have set your desired show it can be changed at a...

Page 10: ...DOWN buttons until Yes is displayed press ENTER to confirm To deactivate Pan inversion select No and press Enter TINT Tilt Inversion 1 Press the MENU button until TINT is displayed press ENTER Either Yes or No will be displayed 2 To activate the tilt inversion press the UP or DOWN buttons until Yes is displayed press ENTER to confim To deactivate tilt inversion select No and press Enter BALA With ...

Page 11: ...s so that TINT is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Operation Universal DMX Control This function allows you to use a Elation universal DMX 512 controller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your i...

Page 12: ...or as a Slave 1 Using approved DMX data cables daisy chain your units together via the XLR connector on the rear of the units Remember the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only For longer cable runs we suggest a terminator at...

Page 13: ... 075 076 078 079 082 083 086 087 089 090 093 094 097 098 101 102 104 105 108 109 112 113 115 116 119 120 123 124 127 128 131 132 135 136 139 140 143 144 147 148 151 152 155 156 159 No function Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color 12 Color 13 Color 14 Color 15 Color 16 Color 17 Color 18 Color 19 Color 20 Color 21 Color 22 Color 23 Color 24 ...

Page 14: ...acro 10 Color Fade Macro 11 Color Fade Macro 12 Color Fade Macro 13 Color Fade Macro 14 Color Fade Macro 15 Color Fade Macro 16 11 CH 12 CH Macro Color Speed 000 255 Color change form slowly to fast 13 CH Pan Tilt Macro 000 015 016 035 036 055 056 075 076 095 096 115 116 135 136 155 156 175 176 195 196 215 216 235 236 255 No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 ...

Page 15: ...15 Photometric Chart Dimmer Curve Chart ...

Page 16: ...ill 3 Clean the external optics with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in Trouble Shooting Trouble Shooting Listed below are a few common problems that you may encounter with solutions No light output from the unit 1 Be sure the exte...

Reviews: