INSTALLATION
PRECAUTIONS
•
When connecting any instrument to the water supply network or booster system,
make sure you observe the protection and disconnect requirements set out in current
safety regulations. (see page 11)
•
When you connect the dosing pump to the water supply line, make sure the
6
water flows into the dosing pump in the direction of the arrows marked on the motor.
•
Never install the dosing pump on top of tanks containing acids or that can potentially
release corrosive or aggressive gases; in any case, always protect it from any such
emissions.
•
Keep the dosing pump away from sources of direct heat. For increased protection, the
Mixtron dosing pump, the only one on the market, is supplied standard with a
thermometer that lets the operator know, through a simple visual check, whether the
pump is operating under optimal conditions or adjustments are needed to avoid
overheating. Indicator is reversible and changes colour from green to red when a
temperature of 40° C (104° F) is reached.
•
If you use your Mixtron unit with a supply pump, we recommend you do not connect it to
the supply
pump’s
suction line (to prevent siphoning).
•
Setting up the
dosage rate is the user’s responsibility. The user is required to
follow the
recommendations of the chemical product’s manufacturer. Mixtron
accepts no liability
for mistakes in the selection of the dosage rate.
•
Make sure the system’s water
pressure and flow comply with the minimum and maximum
specification requirements for proper operation of your Mixtron dosing pump. Mixtron
accepts no liability if the dosing pump does not work due to non-observance of the
minimum and maximum flow and pressure specifications. (see page 2)
•
Adjust the dosage when the device is not under pressure. Check the product regularly to
ensure the dosing pump is drawing the additive correctly.
•
Change the dosing pump’s suction tube as soon as it shows signs of wear or
damage from
contact with the additive or its exposure to the weather elements.
•
Rinse the dosing pump every time the additive is changed and shut off the delivery line
after the last use to avoid leaving the system pressurized.
•
Assemble and tighten plumbing fittings by hand only, without the use of tools.