MityCAM B2521 User Manual Download Page 3

 

 

MityCAM-B2521 EPIX XCAP User’s Guide 

 

 

Page 3 of 13 

60-000014 

 

 

May 13, 2015 

 

 

www.criticallink.com

 

1

 

Installing Laptop Express Card 

1.1

 

Insert the EPIX Installation CD/DVD into your Windows PC. 

1.2

 

It should open an installation type dialog box. Select “XCAP Imaging Application for Win 8/7/Vista – 

64-

Bit”.

 

1.3

 

Complete the setup process using all default settings and OK through prompts. 

1.4

 

Once complete you will be prompted for an activation key, enter: 

1.4.1

 

M8CB/3G3R/NHZU 

1.4.2

 

This is for the “Lite” version 

1.5

 

At some point you should be prompted to install the Capture Driver (dialog that occurs and process taking 

usually 1 second). 

1.6

 

Close all applications and insert the Express Card EPIX Camera Link card into your card slot.  

1.7

 

Once Windows says that the device has “been installed properly” reboot your PC. 

1.8

 

Once rebooted open the PIXCI Application (recommend “run as administrator” by right clicking). 

1.9

 

It should open without any error or driver warnings/messages at this time and be sitting at the 

configuration and viewer screens. 

1.10

 

Continue to the “Using the Camera in Single Camera Link mode (Laptop)” section of this document. 

2

 

Using the Camera in Single Camera Link mode (Laptop) 

2.1

 

Open “XCAP for Windows” from the Desktop Shortcut. 

2.2

 

Say “OK” to the dialog that is shown on startup. 

2.3

 

Set your settings for each of the “Generic Camera Link: Capture and Adjust” options. 

2.3.1

 

Configure ( Figure 1 ) with following alternate settings: 

2.3.1.1

 

Camera Link Base 

2.3.1.2

 

Either 8 bit x 2 (28 FPS) or 16 bit x 1 (14 FPS) 

2.3.2

 

Resolution ( Figure 2 ) 

2.3.3

 

Mode ( Figure 3 ) 

2.3.4

 

Multi-Tap ( Figure 4 ) 

2.4

 

Connect the Camera Link cable from the ExpressCard to the “Camera Link 1” connector (near the USB port) 

on the camera. 

2.5

 

Plug the power connector into P200 on the camera (

Not the GPIO connector w/6-pins

). 

2.6

 

Wait until the Green LED is on. 

2.7

 

In the XCAP utility menu configure the serial port. 

2.7.1

 

Open the PIXCI Serial Terminal Window ( Figure 5 ). 

2.7.2

 

Go into the “Controls” -> “Setup” menu ( Figure 6 ). 

Summary of Contents for B2521

Page 1: ...Page 1 of 13 60 000014 May 13 2015 www criticallink com MityCAM B2521 EPIX XCAP User s Guide CT031 Revision 1 ...

Page 2: ... Configuration 10 10 Image Capture Example 13 11 Revision History 13 Figures Figure 1 Configure Configuration Menu 6 Figure 2 Resolution Configuration Menu 7 Figure 3 Mode Configuration Menu 8 Figure 4 MultiTap Configuration Menu 9 Figure 5 PIXCI Serial Terminal Window 10 Figure 6 Controls Setup Menu 10 Figure 7 Configure Serial Port Enable 115200 8n1 11 Figure 8 Set Bits per Pixel to 16 default i...

Page 3: ...ight clicking 1 9 It should open without any error or driver warnings messages at this time and be sitting at the configuration and viewer screens 1 10 Continue to the Using the Camera in Single Camera Link mode Laptop section of this document 2 Using the Camera in Single Camera Link mode Laptop 2 1 Open XCAP for Windows from the Desktop Shortcut 2 2 Say OK to the dialog that is shown on startup 2...

Page 4: ...image from the sensor in the main viewer window Figure 11 2 10 You may need to rotate the image if mounted on a tripod In the Generic Camera Link Capture and Adjust window open the Proc tab on the left side and select Bottom R L 3 Single Camera Link Notes 3 1 Max FPS Info Note Due to the bandwidth limitations of a single PCI e slot effectively what the Express card slot is the FPS is limited to 28...

Page 5: ... P200 on the camera not the GPIO connector w 6 pins 4 7 Wait until the Green LED is on 4 8 In the XCAP utility configure the serial port 4 8 1 Open the PIXCI Serial Terminal Window Figure 5 4 8 2 Go into the Controls Setup menu Figure 6 4 8 3 Enable the serial port set it as 115200 baud rate and 8 n 1 Figure 7 4 8 4 Send the SBPP 1 command to set the camera to 16 BPP x 5 default is 8 BPP x 10 Figu...

Page 6: ...MityCAM B2521 EPIX XCAP User s Guide Page 6 of 13 60 000014 May 13 2015 www criticallink com 5 Configure Figure 1 Configure Configuration Menu ...

Page 7: ...MityCAM B2521 EPIX XCAP User s Guide Page 7 of 13 60 000014 May 13 2015 www criticallink com 6 Resolution Figure 2 Resolution Configuration Menu ...

Page 8: ...MityCAM B2521 EPIX XCAP User s Guide Page 8 of 13 60 000014 May 13 2015 www criticallink com 7 Mode Figure 3 Mode Configuration Menu ...

Page 9: ...MityCAM B2521 EPIX XCAP User s Guide Page 9 of 13 60 000014 May 13 2015 www criticallink com 8 MultiTap Figure 4 MultiTap Configuration Menu ...

Page 10: ...MityCAM B2521 EPIX XCAP User s Guide Page 10 of 13 60 000014 May 13 2015 www criticallink com 9 Serial Configuration Figure 5 PIXCI Serial Terminal Window Figure 6 Controls Setup Menu ...

Page 11: ...MityCAM B2521 EPIX XCAP User s Guide Page 11 of 13 60 000014 May 13 2015 www criticallink com Figure 7 Configure Serial Port Enable 115200 8n1 Figure 8 Set Bits per Pixel to 16 default is 8 ...

Page 12: ...MityCAM B2521 EPIX XCAP User s Guide Page 12 of 13 60 000014 May 13 2015 www criticallink com Figure 9 Send STRT Command to Begin Capture Figure 10 Send STOP Command to Halt Capture ...

Page 13: ... 13 2015 www criticallink com 10 Image Capture Example Figure 11 Image Capture Example 11 Revision History Revision Date Author Description 1A 3 7 2014 Alex Block Initial Release 1B 5 13 2015 Mike Williamson Add Critical Link style guide and document number markings ...

Reviews: