15
3 Installation onto the Machine Main Unit
No. 99MBE048B
3.3
Mounting the Detector Bracket and Detector
NOTICE
Do not directly touch the I/F Box pins during installation. Otherwise, electronic parts may be damaged by static
electricity. Be sure to take measures to prevent static electricity for installation.
To use the scale with the Detector mounted, the machine main unit, as well as the attachment brack-
et, must be electrically grounded. Failure to do so may cause the scale unit and the Detector to be
affected by external noise. When it is difficult to ground due to the characteristics of the bracket mate
-
rial, make sure that the shielded part of the Detector cable is grounded using a ground bar.
Ground bar etc.
Detector cable
Example: Drawing of using a ground bar
Shielded wire (mesh wire)
Partially cut the vinyl coat-
ing of the cable.
1
Peel the protection tape (blue) off the detecting surface of the Detector.
Protection tape
Back of the Detector