Optional Adapters
Adapter configurations for connecting between a current linear scale
(AT100 series) and an older counter
No adapter required
No connection possible
Current Linear Scale
!4
!4
Older counters other than the above mentioned
No adapter required
Adapter 5C
(OrderNo.09AAA198)
Current Linear Scale
!4
!4
Older counters
K counter
+,¬+3¬+,$ ,¬+,$ ,¬+,$ ,
1.
«M¬COUNTER¬
(old counters with a
RESOLUTION¬OF¬«M
!,# ¬!,#
W
¬!,# 4¬%,
C
¬,# ¬&,$ ¬
' ,0¬' ,0
W
¬' ,$ ¬' -,¬' -,
W,
-,0
,
-,07¬-,%¬-,%7¬-,#
W,
-,$ ¬0,,¬:¬AXIS¬OF¬0,, ,¬::U¬AXIS¬OF¬0,,,
2.
«M¬COUNTER
(old counters with a
RESOLUTION¬OF¬«M
&,#
2
¬&,# ¬' ,0
T,
' -,4¬0,
L,
0,,
«M¬COUNTER¬
(old counters with a
RESOLUTION¬OF¬«M
-,0¬-,0
W
¬-,$ ¬!,# ¬,#
W,
!,# 4¬' ,0¬' ,0
W
¬' ,04¬' ,$
,
&,# ¬&,#
2
¬&,# ¬-,¬' -,
W, GML-
4¬&,$ ¬,,¬¬0,
L
¬0,
L
¬0,,
«M«M¬COUNTER¬
(old counters with a
resolution selectable
BETWEEN¬«M¬AND¬«M
0'
L
¬0'
L
¬0' ,¬0-
L
¬0-
L
¬0-,¬0,$
L,
0,$
L
¬0,$ ,¬0,$ !,¬8¬AXIS¬OF¬0,, ,¬8¬AXIS¬OF¬0,,,
Adapter 5CV
(Order No.09AAA198V)
Adapter 1C
(Order No.09AAA181)
Older counters
/LD¬!4¬SERIES
!4 ¬!4
«M¬SCALE
AT-2, AT2-
.¬!4¬!4.¬!4.¬!4 .
«M¬SCALE
AT2-F
.¬!4&.¬!4
2
No adapter required
Adapter 5S
(Order No.09AAA207)
No connection possible
Current counter
KA
KLD-200
Adapter configurations for connecting between
a current counter and an older linear scale
Limit Output Adapter
If an older limit output counter is replaced with a current counter,
the limit output cable connected with the older counter is made
available by relaying the limit output adapter.
Connection compatibility table
Older counter model to be replaced
Succession model
,IMIT¬OUTPUT¬ADAPTER¬.O
-,$ .¬-,$ .
+,$
907872
-,$ .¬-,$ .¬
+,$
' ,$ 2¬' ,$ 2
+,$
' ,$ 2¬' ,$ 2
+,$
&,$ 2¬&,$ 2
+,$
+,$ ,¬0,$ ,
+,$
.O¬ADAPTER¬REQUIRED
+,$ ,¬0,$ ,
+,$
Note 1
) Limit counters other than the above-mentioned are not compatible since there is no model with the same
specification.
Note 2
) The limit output adapter is dedicated to a relay output.
If any of the above counters uses a photocoupler output, the limit output cable must be remanufactured.
Line Conversion Adapters
These are adapters for connecting between a line driver output linear
scale, or linear gage, and the KA counter.
Adapter configurations for connecting between
a line driver output model and the KA counter
Applicable model
Line Conversion Adapters
Square-wave output AT scale
!4 ¬!4 ¬!4
!DAPTER¬!¬¬!# "
Square-wave output ST scale
34"¬34# ¬34"¬34# ¬
34"¬34# ¬34 "¬34 # ¬
ST422, LH23C, LHS33C
!DAPTER¬"¬
¬!# "
Origin-marked linear gage
,' &:,¬SERIES
!DAPTER¬# ¬¬!# "
Standard-type linear gage
,' &¬SERIES¬,' +¬SERIES¬,' "¬
SERIES¬,' ¬MMSTROKE¬TYPE¬
,' -¬MMSTROKE¬TYPE
!DAPTER¬$ ¬¬
!# "
Note 1
) For the specifications of square-wave output linear scales and linear gages, refer to the control linear
SCALE¬SYSTEM¬CATALOG¬.O ¬AND¬LINEAR¬GAGE¬CATALOG¬.O
Note 2
¬ 4HIS¬CONNECTION¬REQUIRES¬A¬CABLE¬BETWEEN¬ADAPTER¬"¬AND¬THE¬COUNTER¬
¬
5SE¬EITHER¬OPTIONAL¬34¬SIGNAL¬CABLES¬ MMM¬OR¬MAKE¬A¬CABLE¬UP¬TO¬THE¬COUNTER¬USING¬THE¬STANDARD¬
accessory connector for ST scales.
Other adapters can be used by directly connecting to the counter.
CAUTION
The maximum response speed when using one of the above
adapters is determined by the resolution of a the associated
scale.
Connected model's resolution
Maximum response speed
UM
300mm/s
UM
MMS
0.2um
60mm/s
UM
30mm/s
Older counters
KA, KLD-200, KS, KL,
+,$ ,
,
+,$ ,
,
+,$ ,
, KE
Adapters for Connecting between Older and Current Products
A specific adapter may be required for connecting between an older product and a current product. For applicable connecting adapters, refer
to the following configuration diagrams. An adapter is connected to the input connector on a counter.
)T¬IS¬NOT¬POSSIBLE¬TO¬CONNECT¬A¬«M¬SCALE¬OLD¬LINEAR¬SCALE ¬AND¬CURRENT¬C!¬+,$ ¬
!LSO¬LINEAR¬SCALE¬!4¬AND¬AN¬OLDER¬COUNTER¬OTHER¬THAN¬+!¬AND¬+,$ ¬CANNOT¬BE¬CONNECTED