Level 3 Service Manual
GALAXY ASTRAL GEO GEO WAP
Version E
Mitsubishi Electric Telecom Europe SA
Date: 04/00
ZA le Piquet 35370 Etrelles
Phone: +33 2 99 75 71 00
10/29
Fax: + 33 2 99 75 71 47
2.7
Power off.
PWRKEY
t
3s
BBPWR
MUPSU
t
5s
2.8
Real Time Clock (Geo and Geo WAP)
Real time clock lives in ONE C (IC300) and energy is provided :
•
By IC100 (pin 48) via D105, when the main battery is connected.
•
By BT100 (back up battery) via D105, when the main battery is empty or not connected
IC300
VDD_RTCVCC
D105
C305
IC100
REG80
BT100