STERAPORE 5600 Series (FF) Instruction Manual
58/59
10-2
Module Specifications
Product specifications for modules are given below.
Specifications indicated in this manual may be subject to change without notice.
Please select a hoist and other equipment for lifting modules while taking the weight of the module, chains
and connecting pipes into account. If the product has been operated at a trans membrane pressure
significantly beyond the range specified in this manual, it is possible that an extreme amount of clogging has
occurred, which may cause the product to exceed its wet weight.
Table 10-2
Module Specifications List (Element used: 56E0040SA)
Item
Unit
Specifications
Module model number
-
56M0400FF 56M0800FF 56M1200FF 56M1600FF
56M2400FF
Element
Model no.
-
56E0040SA
No. of elements
pcs.
10
20
30
40
60
Dimensions (D×W×H)
mm
30 × 1,250 × 2,000
Nominal membrane surface area
m
2
40
M
o
du
le
Module membrane surface area
m
2
400
800
1200
1600
2400
Dimensions
Depth
mm
1,524
1,524
1,524
1,524
1,524
Width
mm
940
1,390
1,870
2,320
3,416
Height
mm
2,798
2,798
2,798
2,798
2,798
Weight
Dry
kg
400
600
800
1,000
1,550
Lifting
*
1
kg
500 to 1,000 800 to 1,800 1,100 to 2,600 1,400 to 3,400 2,100 to 5,100
No. of permeate adapters
required
pairs
20
40
60
80
120
Connection to treated water
(JIS10K)
-
65A Flange
× 2
65A Flange
× 2
65A Flange
× 2
65A Flange
× 2
65A Flange
× 4
Guide pipe specifications
-
50A
50A
80A
80A
80A
Diffuser
part
Diffuser
Model number
-
FB-10W
FB-20W
FB-30W
FB-40W
FB-60W
Connection (JIS10K)
80A Flange
80A Flange
80A Flange
80A Flange
80A Flange × 2
Diffuser
air
Minimum aeration rate
Nm
3
/min
0.8
1.5
2.2
2.9
4.4
Maximum aeration rate
Nm
3
/min
1.7
3.1
4.5
5.9
9.0
Standard aeration rate
Nm
3
/min
1.5
2.7
3.8
5.0
7.7
Diffuser pressure loss
(Maximum)
kPa
1.1
1.1
1.1
1.1
1.1
Minimum water depth
m
3.0
3.0
3.0
3.0
3.0
Standard
center-to-center
distance for modules
Depthwise
2.2 m or greater (The wall-to-c enter distance for modules adjacent to
walls must be 1.1 m or greater.)
Widthwise
Secure a sufficient distance for tying in pipes or lifting the module.
O
p
e
ra
tin
g
co
nd
iti
o
n
s
Filtration mode
-
Submerged suction filtration (out-in filtration)
Normal trans membrane pressure
-
Initial trans membrane pressure: -15 kPa or above
Normal temperature
℃
5 to 40
pH range of raw water
-
5 to 9
Oil content range of raw water
-
Normal hexane extracts 150 mg/L or below (excluding mineral oils)
pH range for cleaning
-
1.0 to 11.0
MLSS range
(Membrane Tank)
mg/L
Recommended range of application: 5,000 to 10,000
(min: 3,000; max: 15,000)
Design filtration flow
*
2
m
3
/(day
・
module)
80 to 320
160 to 640
240 to 960
320 to 1,280
480 to 1,920
Other
-
Silicon antifoaming agent may not be used.
*1
Reference lifting weight when wet. The actual lifting weight differs according to the operating conditions and the
amount of adhered sludge.
*2
Design filtration flow is calculated based on the assumption that flux is between 0.2 and 0.8 m
3
/(m
2
•d). It differs
according to the raw water conditions, operating temperature, etc.
Standard accessories
Water collection adapter
(permeate adapter)
Accessories not included
Guide rail
Chains and shackles
Chain blocks and cranes
Slings and lifting beams
Filtered water hose and pipes, air
hose and pipes
Protective sheets and covers