background image

– 14 –

Are the batteries running down? 

   Page 13

Replace the batteries with new ones and repeat the operation.

Operating hints

Please observe the following for the most economic and comfortable use of your unit.

Set a suitable room temperature.

Excessively high or low temperatures are not
good for your health and waste electricity.

Avoid direct sunlight and draught.

Cut out direct sunlight by drawing the cur-
tains or blinds when cooling. Keep windows
and doors shut, except when ventilating.

Operate the unit only when needed.

Use the timer properly to operate the unit
only when needed.

Don’t drop the remote control.
Handle with care.

Clean the filters frequently.

Clogged filters may block the air flow and
cause less efficient operation.

Don’t go near high temperature
places, such as an electric carpet
or stove.

Adjust the airflow direction properly.

Adjust the up/down and left/right airflow to
ensure a steady room temperature.

Do not place heavy objects on the
remote controller, or step on it.

Warning note for remote control handling

Don’t put any obstructing obsta-
cles between the remote control
and the unit.

Don’t spill water etc on the remote
control.

Don’t leave the remote control ex-
posed to direct sunlight or other
strong lighting.

Generate little heat when cooling.

Keep heat sources out of the room as much as
possible.

When the operation fails with the remote control

If the operation still fails, handle as per emergency
run operation.
Contact your dealer.

   Page 13

suitable
temperature

RKT012A754_En.p65

05.9.14, 1:43 PM

14

Summary of Contents for SRK50CE-S1

Page 1: ...ctiva 73 23 EEC Este aparelho de ar condicionado est em conformidade com a Directiva EMC 88 336 CEE e a Directiva LV 72 23 CEE EMC 88 396 LV 73 23 USER S MANUAL AIR CONDITIONER RKT012A754 ENGLISH MANU...

Page 2: ...EAT DRY FAN mode operation procedure 9 Concerning HIGH POWER operation 9 Concerning ECONOMY operation 9 Air flow direction adjustment procedure 10 About FAN SPEED 10 OFF TIMER operation procedure 11 O...

Page 3: ...ble may produce an electric shock Depending on the place of installation a circuit breaker may be necessary If you don t fit a circuit breaker you may cause an electric shock Do not install near place...

Page 4: ...combustible insecticide or paint spray near the blower nor aim it directly at the system This may result in a fire Do not place anything containing wa ter like vases on top of the unit Water entering...

Page 5: ...when switched on Characteristics Amenity facility TIMER procedure HI POWER mode Page 12 When using the timer to switch on the sys tem become operational shortly before the set time depending on the ro...

Page 6: ...deodorizing filter Natural enzyme filter Refrigerant piping connection electric flex Up down air flow direction adjustment flap Page 10 Wireless remote control Page 7 Drain hose Drains water from the...

Page 7: ...ge 13 Removal installation of air inlet panel ECONOMY light orange Illuminates during ECONOMY operation HI POWER light green Illuminates during HIGH POWER operation RUN HOT KEEP light green Illuminate...

Page 8: ...e 11 TEMPERATURE button This button sets the room temperature This button changes the present time and TIMER time CANCEL button This button cancels the ON timer and OFF timer RESERVE button This butto...

Page 9: ...adjustment procedure Page 10 NOTE WARM Press the button COOL Press the button 1 When a change in temperature is desired Press the or button Air is not blowing out during the op eration Page 17 If you...

Page 10: ...display is erased Concerning ECONOMY operation Pressing the ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating The unit operates 1 5 C...

Page 11: ...hen in COOL or DRY operation do not operate for hours on end with the air flow blowing straight down Otherwise condensation may appear on the outlet grill and drip down Do not try to adjust the flaps...

Page 12: ...Releasing procedure Press the CANCEL button to turn off the timer indicator ON TIMER operation procedure 1 2 Changing of set time Set a new time by using the ON TIMER button Example In the case you w...

Page 13: ...cator About TIMER operation About Amenity facilities Amenity facilities enable to start the operation a little earlier so that the room approaches optimum tempera ture at ON time when the operation is...

Page 14: ...ttery conforming to JIS or IEC is 6 to 12 months with normal use If used longer or when an unspecified battery is used liquid may leak from the battery causing the remote control to malfunction Remove...

Page 15: ...frequently Clogged filters may block the air flow and cause less efficient operation Don t go near high temperature places such as an electric carpet or stove Adjust the airflow direction properly Ad...

Page 16: ...soft dry cloth There s a danger of electric shock Cleaning If the filter is very dirty clean it with warm water approx 30 C and dry it thoroughly CAUTION Don t clean the filters with boiling water Don...

Page 17: ...the air filters 2 Remove the filter holders with the natural enzyme filter and the photocatalytic washable deodorizing filter installed in the holders from the air conditioner 3 Remove the natural enz...

Page 18: ...restart the unit immediately after you have stopped it RUN light is on Not operating Air is not blown out when starting the HEATING operation RUN light blinks slowly 1 5 sec ON 0 5 sec OFF Air flow h...

Page 19: ...he unit is operated for a long time in high humidity moisture may form on the air outlet grilles and start dripping You hear a slight gurgling sound This is caused by refrigerating liquid moving withi...

Page 20: ...conditioner operating conditions Use within the following operational range Operating outside of this range may result in the protection devices being activated preventing the unit from working Coolin...

Page 21: ...r sensor error 2 time flash 6 time flash TIMER light ON 1 time flash RUN light 2 time flash 1 time flash TIMER light RUN light keeps flashing Over heat of compressor Error of signal transmission 5 tim...

Page 22: ......

Reviews: