54
-
'12 • SRK-T-130
'09•SRK-DB-087D
(7) Inspection procedures corresponding to detail of trouble
Sensor error
Sensor temperature characteristics (Room
temp., indoor heat exchanger temp., out-
door heat exchanger temp., outdoor air
temp.)
Temperature (˚C)
Resistance (k
)
30
25
20
15
10
5
30
20
10
40
50
60
70
0
-10
Discharge pipe sensor temperature characteristics
Indoor fan motor error
Broken sensor wire,
connector poor connection
0
0
20
40
60
80
100
120 135
20
40
60
80
100
120
140
160
180
Temperature (˚C)
Resistance (k
)
Defective fan motor, connector poor
connection, defective indoor PCB
59 for the fan motor and indoor PCB check pro-
Power supply reset
Is it normalized?
Malfunction by temporary noise
Replace fan motor. (If the
error persists after replacing
the fan motor, replace the
indoor PCB.)
Summary of Contents for SRC92ZL-S
Page 2: ...TECHNICAL MANUAL...
Page 8: ...12 SRK T 130 3 Remote control a Wireless remote control Unit mm 60 17 3 150...
Page 55: ...53 12 SRK T 130 Service data record form 47...
Page 75: ...73 12 SRK T 130 3 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control...
Page 76: ...74 12 SRK T 130...
Page 77: ...75 12 SRK T 130 PARTS LIST INDOOR UNIT SRK92ZL S OUTDOOR UNIT SRC92ZL S...
Page 81: ...79 12 SRK T 130 MEMO...
Page 84: ...82 12 SRK T 130 CRBE0347 5 14 15 13 13 15 16 2 3 4 6 12 15 9 10 7 11 15 15 8 1 2 0 55...
Page 86: ...84 12 SRK T 130 CRBE0348 5 1 17 6 2 3 16 9 4 18 14 19 10 8 15 7 12 13 61 1 2 11 5 3 6 55...