9.18 Z(P).UINI
9
DEDICATED INSTRUCTIONS
9.18 Z(P).UINI
For Universal model QCPUs, the station No. of a normal station (own station) can be set.
(
Section 4.5 Station No. Setting by Sequence Program)
For use of the UINI instruction, select "Specify station No. by program." in Network
parameters. (
* 1 " " (double quotation) of the first argument can be omitted.
(1) Setting data
* 1 Local devices and file registers for each program cannot be used as devices in setting data.
Table 9.95 Devices available for setting data
Setting
data
Available devices
Internal device
(System, User)
File
register
Link direct device
J \
Intelligent function
module device
U \G
Index register
Zn
Constant
Others
Bit
Word
Bit
Word
K, H
$
(S1)
—
—
(D1)
—
Figure 9.138 Instruction format
Table 9.96 Setting data
Setting data
*1
Description
Data type
"Un"/Un
Start I/O number of the own station's CC-Link IE controller network
module
(00 to FE
H
: The higher two digits of the 3-digit I/O number)
String/
Binary 16 bits
(S1)
Start device of the own station that stores control data
(
Device name
(D1)
The own station's device that is turned on for one scan upon
completion of the instruction
(D1)+1 also turns ON if the instruction execution has failed.
Bit
Z.UINI
"Un"
*1
*1
(S1)
(D1)
ZP.UINI
"Un"
(S1)
(D1)
Z.UINI
Start contact
[Instruction format]
[Execution condition]
[Instruction symbol]
ZP.UINI
Start contact