6
FUNCTIONS
6.20 CPU Module System Display by GX Developer
6
- 157
1
O
verv
iew
2
Per
fo
rma
nce
S
p
ecifica
tio
n
3
S
equ
en
ce P
ro
g
ra
m
Co
nfig
ura
tio
n a
nd
E
xecut
io
n Co
nd
iti
o
ns
4
I/O N
unb
er
Assig
n
m
e
nt
5
Me
mor
ie
s a
nd
File
s
Ha
nd
led
by CP
U Mo
du
le
6
Func
tions
7
Co
mmu
nic
a
tion
us
in
g
bu
ilt
-i
n E
th
e
rne
t po
rt
s o
f
CP
U mod
u
le
8
Co
mm
un
icatio
n
w
ith
Int
e
lli
ge
nt
Fun
ction
Mo
du
le
(1) Installed status
Enables the controlling CPU, the model an07 d the number of modules mounted onto
the selected base unit to be confirmed.
"Not installed" will be displayed for slots in which modules have not been mounted.
When slots have been set as "Empty" at the "I/O assignment" tab screen in the "(PLC)
Parameter" dialog box, the module's model will not be displayed when if a module has
been mounted.
Note66
When the redundant base module is used, the power supply module mounting status
is also displayed.
When the redundant CPU is used, redundant CPU status is also displayed.
Note67
(2) Parameter status
Enables the I/O number, the module type and the number of modules mounted for
each of the slots on the selected base unit to be confirmed.
If the operation status shows 0 empty points and an allocation error is displayed, it
means that the PLC parameter's I/O allocation and the actual status are different.
Match the I/O assignment of the PLC parameter dialog box to the actual mounting
status.
When the Redundant base unit is used, the power supply module mounting status is
also displayed.
Note68
(3) Base
Enables the status of the modules mounted onto the base unit in use to be confirmed.
When there is at least one error module, the Module field turns to the status color of
that error module.
(4) Mode
Note69
Used when online module change is executed.
Refer to the following manuals for online module change.
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
Manual of the module compatible with online module change
Note66
Note67
Note68
Note69
Basic
Note6.64
When the Basic model QCPU is used, the control CPU of the module is not displayed.
Basic
Basic
Note6.65
Universal
UD
Note6.66
When the Basic model QCPU is used, the power supply module mounting status.
Basic
Universal
UD
Basic
To monitor the Universal model QCPU mounting status, check the versions of CPU module and
GX Developer.
Universal
UD
Basic
High
Performance
Universal
UD
Note6.67 Note6.67
Since online module change cannot be executed for the Basic model QCPU, High Performance
model QCPU and Universal model CPU mode selection is not available.
Basic
High
Performance
Universal
UD