PUMY-P YHMB(-BS)

OUTDOOR UNIT

S Series

Specifications

Note: 

1 Nominal cooling conditions

Indoor 27˚CDB/19˚CWB (81˚FDB/66˚FWB), Outdoor 35˚CDB (95˚FDB)
Pipe length 7.5m (24-9/16ft), Level difference 0m (0ft)

2 Nominal heating conditions

Indoor 20˚CDB (68˚FDB),Outdoor 7˚CDB/6˚CWB
Pipe length 7.5m (24-9/16ft), Level difference 0 m (0 ft)

Power source
Cooling capacity 
(Nominal)

Temp. 
range of 
cooling
Heating capacity
(Nominal)

Temp. 
range 
of heating
Indoor unit
connectable
Sound pressure level
 (measured in anechoic room)
Diameter of 
refrigerant pipe
External finish
External dimension H 

 W 

 D

Net weight
Heat exchanger

Compressor 

FAN

HIC circuit (HIC: Heat Inter-Changer)

Protection

Defrosting method
Refrigerant

Power input
Current input
COP (kW/kW)
Indoor 
Outdoor

Power input
Current input
COP (kW/kW) 
Indoor temp. 
Outdoor temp.

Total capacity
Model/Quantity

Liquid
Gas

Type
Maker
Starting method
Motor output
Case heater
Lubricant
Air flow rate
External static press.
Type 

 Quantity

Control, Driving mechanism
Motor output

High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Fan motor

Type 

 Original charge

Control  

PUMY-P100YHMB(-BS)

PUMY-P125YHMB(-BS)

PUMY-P140YHMB(-BS)

kW

BTU/h

kW

A

W.B.

D.B.

kW

BTU/h

kW

A

D.B.

W.B.

dB<A>

mm(in.)
mm(in.)

mm (in.)

kg (lb)

kW
kW

m

3

/min

kW

1

1

2

2

11.2

38,200

3.30

5.28-5.02-4.84

3.39

12.5

42,700

3.63

5.81-5.52-5.32

3.44

P15 ~ P125 / 1 ~ 8

49/51

1.9

-

15.5

52,900

5.32

8.51-8.09-7.80

2.91

18.0

61,400

5.32

8.51-8.09-7.80

3.38

P15 ~ P140 / 1 ~ 12

51/53

2.9

-

3-phase, 380-400-415V, 50Hz

15 ~ 24˚C  (59~75˚F)

- 5 ~ 46˚C  (23~115˚F)

10 to 46˚C D.B.(50 to 115˚FD.B.) : in case of connecting PKFY-P15/P20/P25 type indoor unit.

15~27˚C (59~81˚F)
-15~15˚C  (5~59˚F)

50 ~ 130% of outdoor unit capacity

ø9.52 (ø3/8)  Flare 

ø15.88 (ø5/8)  Flare

Galvanized steel sheet<MUNSELL 3Y 7.8/1.1>

1,350 

 950 

 330 (53-3/16 

 37-7/16 

 13)

140 (309)

Salt-resistant cross fin & copper tube

Inverter scroll hermetic compressor

Mitsubishi Electric Corporation

Inverter

FV508

100

0 Pa

Propeller fan 

 2

DC-control, Direct-driven by motor

0.06 x 2

-

High pressure sensor, High pressure switch 4.15 MPa

Over-heat protection, Over-current protection

Discharge thermo protection, Over-current protection

Over-heat protection, Voltage protection

Auto-defrost mode (Reversed refrigerant circle)

  R410A 

 8.5kg ( 19 lb)

LEV  circuit 

14.0

47,800

4.27

6.83-6.49-6.26

3.28

16.0

54,600

4.29

6.87-6.52-6.29

3.73

P15 ~ P140 / 1 ~ 10

50/52

2.4

-

PUHY-P Y(S)HM-A(-BS)

PUHY-EP Y(S)HM-A(-BS)

OUTDOOR UNIT

Y (Heat Pump) series

Cooling or Heating

The CITY MULTI Y series makes use of a two-pipe refrigerant system, which allows for system changeover from cooling to 
heating, ensuring that a constant indoor climate is maintained in all zones. With a wide line-up of indoor units in connection 
with a flexible piping system, the CITY MULTI Y series can be configured for all applications. Depending on capacity, up to 50 
indoor units can be connected with up to 130% connected capacity to maximize an engineer

'

s design options. This feature al-

lows easy air conditioning in each area with convenient individual controllers.

The two-pipe zoned system designed for Heat Pump Operation

Outdoor unit

Indoor unit

Between indoor units 
top-bottom differential
15m [49ft]

Furthest piping length 
190m [623ft] (equivalent length) 
(actual length 165m [541ft])

Refrigerant Piping Lengths
Total length
Maximum allowable length

Farthest indoor from first branch

Vertical differentials between units
Indoor/outdoor (outdoor higher)
Indoor/outdoor (outdoor lower)
Indoor/indoor

Maximum meters [Feet]
1,000[3,280]
165 (190equivalent)
 [541(623)]
40 [131]

Maximum meters [Feet]
50 [164]*1
40 [131]*1
15 [49]

Indoor unit

Header

Indoor unit

Indoor unit

Joint

Outdoor unit

[8-50HP (Y series)]

[8-36HP (High COP Y series)]

*1 When the outdoor unit is installed below the indoor unit, top-bottom differential is 40m [131 ft].
*2  Depending  on  the  model  and  installation  conditions,  top-bottom  differential  90m  [295ft]  (o/u  above)  and  60m  [196ft]  (o/u  below)  is 

available. For more detailed information, please contact your nearest sales office or distributor.

Top-bottom differential 
50m [164ft] *1 *2

Page97