241
APPENDICES
A
Appendix 1 Details of R
emote I/O Signa
ls
Appendix 1.1 Details of r
emote input sig
nals
RX21
CH1
Preset/replace
completion
• This signal turns on when the preset is completed by turning on CH
Preset/replace
command (RY21, RY39).
• This signal turns off when CH
Preset/replace command (RY21, RY39) is turned off.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after the preset is completed.
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX39
CH2
RX23
CH1
External
preset/replace
(Z Phase)
request
detection
• This signal turns on when a count value is replaced with the preset value by CH
Phase Z
input terminal (Z1, Z2). Note that this signal does not turn on when Z phase (Preset) trigger
setting (address: 0125
H
.b0 to b1, 0145
H
.b0 to b1) in CH
Phase Z setting (address: 0125
H
,
0145
H
) is set to During ON (11).
• This signal turns off when CH
External preset/replace (Z Phase) request detection reset
command (RY23, RY3B) is turned on.
• The value is not replaced while this signal is on.
• Note that this signal does not turn on when External preset/replace (Z Phase) request
detection setting (address: 0125
H
.b4, 0145
H
.b4) in CH
Phase Z setting (address: 0125
H
,
0145
H
) is set to Not ON at detection (1). This signal turns on only when External
preset/replace (Z Phase) request detection setting (address: 0125
H
.b4, 0145
H
.b4) is set to
ON at detection (0).
• The following figure shows the case when Z phase (Preset) trigger setting (address:
0125
H
.b0 to b1, 0145
H
.b0 to b1) in CH
Phase Z setting (address: 0125
H
, 0145
H
) is set to
Rising (00).
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after the preset is completed.
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX3B
CH2
Remote input
(RX) No.
Signal name
Description
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF
0
100
100
CH Preset value setting
(RWw14 to RWw15, RWw2C to RWw2D)
CH Preset/replace command
(RY21, RY39)
CH Preset/replace completion
(RX21, RX39)
CH Present value
(RWr10 to RWr11, RWr28 to RWr29)
0
100
100
t
t T
1
CH Preset value setting
(RWw14 to RWw15, RWw2C to RWw2D)
CH Phase Z input terminal
(Z1, Z2)
CH External preset/replace (Z Phase)
request detection
(RX23, RX3B)
CH External preset/replace (Z Phase)
request detection reset command
(RY23, RY3B)
CH Present value
(RWr10 to RWr11, RWr28 to RWr29)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
ON
OFF
OFF
Summary of Contents for NZ2GFCF-D62PD2
Page 1: ......
Page 2: ......
Page 54: ...52 Memo ...
Page 206: ...204 Memo ...
Page 303: ......
Page 304: ......