NR-261UM-07LAN5
DISASSEMBLING PROCEDURES
●
Disassembling procedures
In reverse of assembling procedures.
●
Assembling procedures
1.Screw M082 with the two screws(
Ⓐ
).
2.Screw the COVER-DV3 with the one screw(
Ⓐ
).
3.Connect the FPC to M082.
M3X6
0.7 +0.2/-0.1
Ⓐ
Tighten torque(N
・m)
Screw
No.
Ⓐ
x 2
Ⓐ
M082: ASSY-PCB-CONN
Pass salient to the square hole
on the circuit board.
Fit reentrant on the circuit board
to salient.
Set FPC to COVER-DV3.
Lock after FPC connected.
FPC