17
P
Inner protector
P
Part name
Measure the resistance between the terminals with a tester.
(Coil wiring temperature-10°C ~ 40°C)
Compressor
(MC1, MC2)
INNER
PROTECTOR
150°C OPEN
90°C CLOSE
Check method and criterion
Figure
MUX-A22WV -
E1
Normal
Abnormal
Open or
short-circuit
C-R
C-S
RN145VHSHT
RN092VHSHT
2.14 ~ 2.63
Ω
3.41 ~ 4.18
Ω
3.35 ~ 4.11
Ω
5.41 ~ 6.63
Ω
Outdoor fan
motor
(MF61)
INNER
PROTECTOR
145
i
8°C OPEN
Measure the resistance between the terminals with a tester.
(Coil wiring temperature -10°C ~ 40°C)
Measure the resistance with a tester. (Part temperature -10°C ~ 40°C)
Normal
1410 ~ 1730
Ω
Abnormal
Open or short-circuit
Normal
Abnormal
Open or
short-circuit
WHT-BLK
BLK-RED
Solenoid coil
21RB, 21R3,
21R4
BLK RED
WHT
P
79 ~ 98
Ω
129 ~ 158
Ω
Color of lead
wire
OB318--1.qxp 03.10.30 0:55 PM Page 17