7-308
7.13 Data Control Instructions
7.13.3 Zone control of 16-/32-bit BIN data
ZONE, DZONE
7.13.3
Zone control of 16-/32-bit BIN data
ZONE, DZONE
ZONE(P)
DZONE(P)
P: Executing condition
:
indicates any of the following
instructions.
ZONE
ZONEP
DZONE
DZONEP
Input argument,
EN:
Executing condition
:Bit
s1:
Negative bias value that is added to the input value
:ANY16/32
s2:
Positive bias value that is added to the input value
:ANY16/32
s3:
Input value for executing the zone control
:ANY16/32
Output argument,
ENO:
Execution result
:Bit
d:
Output value controlled by the zone control
:ANY16/32
Setting
data
Internal device
R, ZR
J
\
U
\G
Zn
Constant
K, H
Others
Bit
Word
Bit
Word
−
−
−
−
−
Universal
UD
High
Performance
Structured ladder
ST
EN
ENO
s
1
d
s
2
s
3
Z
ONE
Z
ONE
(EN,
s
1,
s
2,
s
3, d);
ENO:=
s
1
s
2
s
3
d