312
6 BASIC INSTRUCTIONS
6.6 Data Transfer Instructions
Transferring octal bits (16-bit data)
PRUN(P)
These instructions handle the device number of (s) and (d) with nibble specification as octal numbers, and transfer data.
Setting data
■
Descriptions, ranges, and data types
*1
Make sure that the least significant digit of a specified device number is "0".
■
Applicable devices
*1
B, SB cannot be used.
Processing details
• Octal bit device
Decimal bit device
• Decimal bit device
Octal bit device
Ladder diagram
Structured text
ENO:=PRUN(EN,s,d);
ENO:=PRUNP(EN,s,d);
Operand
Description
Range
Data type
Data type (label)
(s)
Nibble specification
16-bit signed binary
ANY16
(d)
Device number of transfer destination
16-bit signed binary
ANY16
Operand
Bit
Word
Double word
Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB
U
\G
T, ST,
C, LC
T, ST, C, D,
W, SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s)
(d)
(s)
(d)
PRUN
K4X0
K4M0
(s)
(d)
X17
X16
X15
X14
X13
X12
X11
X10
X7
X6
X5
X4
X3
X2
X1
X0
M15
M14
M13
M12
M11
M9
M8
M7
M6
M5
M4
M3
M2
M1
M0
M17
M16
M10
Octal bit device (X)
Do not change.
Decimal bit device (M)
X0 to X17
M0 to M7, M10 to M17
Command
input
PRUN
K4M0
K4Y0
(s)
(d)
Y17
Y16
Y15
Y14
Y13
Y12
Y11
Y10
Y7
Y6
Y5
Y4
Y3
Y2
Y1
Y0
M15
M14
M13
M12
M11
M9
M8
M7
M6
M5
M4
M3
M2
M1
M0
M17
M16
M10
Octal bit device (X)
Decimal bit device (M)
Not transferred
M0 to M7, M10 to M17
Y0 to Y17
Command
input
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......