FEATURES AND CONTROLS
- 6 -
10a
1.
Fuel Tank Cap
2.
Fuel Tank
3.
Fuel Gauge (optional)
4.
Fuel Tank Breathing Valve
5.
Engine Choke Lever
6.
Fuel Shut-off
7.
Air Filter
8.
Recoil Starter
9.
Oil Gauge
10.
Engine Shut-off
10a. Hour Meter
(Only for MBG5500/7000/
MBG7000X)
11.
120 V, 20 Ampere Duplex
Receptacle
or GFCI (optional)
12.
AC Protector
(MBG5500, MBG6500 Only)
13.
Circuit Breaker
14.
120/240 V, 20 Ampere
Twist lock Receptacle
15.
Ground Terminal
16.
Oil Drain Plug
17.
Muffler
18.
Spark Arrester
19.
Carbon Canister
Inspection Window
FULL
EMPTY
Fuel Gauge (3)
(optional)
120 V, 20 Ampere Duplex Receptacle (11)
20 amps of current may be drawn from each half of
the receptacle. However, total power drawn must
be kept within nameplate ratings. These receptacles
may be used along with the twist lock receptacle
provided the generator is not overloaded.
120V, 20 Ampere GFCI Duplex Receptacle (optional)
If your generator comes with GFCI duplex
receptacle, after starting the engine, check the GFCI
for proper functioning by the following test
Push TEST button, The RESET button will pop out. Power is now
off at the outlets protected by the GFCI, indicating that the device
is functioning properly.
If TRIP does not appear when testing, do not use the generator.
Call a qualified electrician.
To restore power, push RESET button.
WARNING
If the RESET button pops out during operation, stop the generator
immediately and call a qualified electrician for checking generator
and the appliances.
The duplex 120V receptacle is protected by a GFCI. GFCI shuts off
the output current from the duplex 120V receptacle when a
ground fault occurs in the generator or the appliance. Please note
that other receptacles are not protected by GFCI.
CAUTION
procedure:
GFCI Duplex Receptacle