background image

24

Installation

Note

A point to notice

Info.

Supplementary information

Setting the Menus (Cont.)

DISPLAY

Setting the display mode  (DISPLAY
MODE)

: Shows date and present time.

: Shows date, day of the week,

present time and recording mode.

: Displays nothing.  In case of  alarm

recording, displays same items as
DISPLAY MODE 2.

: No date or time display.

* shown when DISPLAY MODE 1, 2 or 3 is selected.

<DISPLAY>

DISPLAY MODE

1

TIME DATE SIZE

SMALL

BLUE BACK

OFF

e.g.<MODE 1>

09-07-’01 00:00:00

Day

Month

Year

Hour

Alarm

Recording

Counter*

Second

Minute

0 9 - 0 7 - ’ 0 1   2 0 : 2 5 : 0 0   A 0 0 0 1

DISPLAY MODE 1

Day

Month

Day of
the Week

Year

Hour

Alarm

Recording

Counter*

Second

Minute

0 9 - 0 7 - ’ 0 1   M O N   A 0 0 0 1
2 0 : 2 5 : 0 0               3

Recording
Mode

DISPLAY MODE 2 and 3

RECORDING SET UP

Setting the alarm recording mode
(ALARM REC MODE)
Sets the alarm recording time mode.

Providing TAPE LENGTH in FIRST
TIME SET UP menu is set to E-
180.
When JOG is turned, the display
will be switched in the order of 3H

 L12H 

 L24H 

 3H 

 ...

Providing TAPE LENGTH in FIRST TIME SET UP menu is
set to E-240.
When JOG is turned, the display will be switched in the
order of 4H 

 L16H 

 L32H 

 4H 

 ...

Setting the alarm recording  duration (ALARM REC
DURATION)
Sets the duration of the alarm recording period.  When JOG is
turned, the display will be switched in the order of 1M (minute)

 2M 

 5M 

 10M 

 MAN1 

 MAN2 

 15S (second) 

30S 

 45S 

 1M 

 ...

Setting the emergency recording (EMERGENCY REC)

ON

: Starts alarm recording when the ALM IN terminal is

grounded while the VCR is recording, in stop mode,
turned off or in stand-by mode for timer recording.

OFF

: Starts alarm recording when the ALM IN terminal is

grounded during recording.

Setting the clog detection (CLOG DETECT)

ON

: The VCR automatically removes any particles that may

accumulate on the heads during time-lapse recording.
If it cannot be entirely removed, a warning “CLOg”
flashes on the fluorescent display (

 page 30).

OFF

: The VCR does not detect clogged head.

Setting the number of fields in one shot recording (ONE
SHOT•FIELD)
Sets the number of recorded fields in the one shot recording
mode.  When JOG is turned, the display will be switched in the
order of 1 

 2 

 3 

 4 

 5 

 10 

 20 

 30 

 1 

  ...

Setting the interval time in the one shot recording (ONE
SHOT•INTERVAL)
Sets the interval time in the one shot recording mode.  When
JOG is turned, the display will be switched in the order of SHOT

 10S (second) 

 15S 

 30S 

 45S 

 1M (minute) 

 2M

 3M 

 SHOT 

 ...

<RECORDING SET UP>

ALARM REC MODE

3H

ALARM REC DURATION

1M

EMERGENCY REC

OFF

CLOG DETECT

ON

ONE SHOT•FIELD

1

ONE SHOT•INTERVAL

SHOT

TIMER PROGRAM

 

 page 11, Timer Recording.

MAIN MENU

DISPLAY

Sets the display format of the date
and present time on screen.

TIMER PROGRAM

Sets the timer recording.

RECORDING SET UP

Sets the alarm recording mode, alarm recording duration
and emergency recording, etc.

REAR TERMINAL

Sets the frequency division ratio of CLOCK OUT, output
signal of CALL OUT terminal and MODE OUT terminal, etc.

MAINTENANCE

Displays the power loss list and alarm list, etc.  Also,
initialises all menu settings, clears the power loss list and
alarm list.

CLOCK/FIRST TIME SET UP

Sets the present time and the operation at the tape end, etc.

<MAIN MENU>

DISPLAY
TIMER PROGRAM
RECORDING SET UP
REAR TERMINAL

MAINTENANCE
CLOCK/FIRST TIME SET UP

Use JOG to select,
and ENTER.
Press MENU to exit.

ENGLISH
DEUTSCH
FRANÇAIS
CASTELLANO
NEDERLANDS
ITALIANO

Use JOG to select,
and ENTER.

LANGUAGE SELECTION

The menu which appears on screen offers 7 languages.
This menu appears by pressing MENU button, when the VCR is
turned on for the first time after the purchase or when RESET
button is pressed during use.

1. Press MENU button.

The menu as shown to the right
appears.

2. Turn JOG to select the desired

language.

3. Turn SHUTTLE to the right.

<MAIN MENU> in the selected
language appears on screen.

4. Press MENU button to exit.

Note

After first time setup and selection of the language to be
used, the only way to go back and access the main menu in
the seven languages is to PRESS the RESET button found
on the rear panel.  The RESET button can be accessed with
a small pointed object.  The RESET button is pressed,
repeat steps 1 to 4 above.

Setting the size of letter for date and present time display
(TIME DATE SIZE)

SMALL : The size of the letters become small.

LARGE : The size of the letters become large.

Setting the background colour (BLUE BACK)

ON

: The blue coloured screen overlays on the recorded

picture when the menu is displayed on the monitor.

OFF

: The recorded picture is overlaid with the menu display.

Note

When the setting is OFF and the video signal is not input,
the blue coloured screen overlays on the recorded picture
when the menu is displayed on the monitor.

When the setting is ON and the video signal is not input, the
background colour will be in blue.  In this case, the warning
“NO SIGNAL” flashes on screen and “noSIg” flashes on the
fluorescent display.

Summary of Contents for HS-1168E

Page 1: ...ATION AND OPERATION MANUAL Only video cassette tapes with the mark may be used with this model This instruction manual is important to you Please read it before using your video cassette recorder DEUT...

Page 2: ...68 EEC The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas business light indu...

Page 3: ...f the cabinet or inserting foreign objects of any kind not only creates a safety hazard but can also cause extensive damage PROTECT THE POWER CORD Damage to the power cord may cause fire or shock haza...

Page 4: ...cording 12 Series Recording 13 Remote Recording 13 Repeat Recording 13 One shot Interval Recording 14 Synchronous Recording 14 Additional Features 15 Memory Backup in Case of Power Failure 15 After a...

Page 5: ...AY MODE buttons Press to select the recording or playback speed TRACKING buttons Press to reduce eliminate the noise during playback slow playback etc POSITION VERTICAL ADJUST buttons When the day and...

Page 6: ...luminates when TAPE END in FIRST TIME SET UP menu is set to REPEAT or ALARM PROT Cassette Status indicator Illuminates when a tape is inserted The light advances stops or flashes corresponding to the...

Page 7: ...ERMINAL menu is set to CLOCK ADJ the clock of all connected VCR s can be adjusted page 22 CLK OUT Use to control an external camera switcher CALL OUT Use to indicate when a tape reaches its end during...

Page 8: ...VCR has a protection circuit which will eject the tape if it is loaded improperly If the VCR ejects the tape remove it completely and check that the long narrow edge with the contents label is facing...

Page 9: ...Press REC PLAY MODE button to select the desired playback mode 4 Press PLAY button to start playback If noise occurs during playback adjust the tracking page 17 5 Press STOP button to stop playback I...

Page 10: ...minutes ahead of the reference time being used After the step 7 above when reference time reaches 00 second of the minute you have chosen turn SHUTTLE to the right The VCR s clock now corresponds to t...

Page 11: ...ART END HR 1 DAY 08 00 20 00 L24SP 2 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L24SP 2 TUE 3 PROGRAM TO RECORD DW START END HR 1 DAY 08 00 20 00 L24SP 2 TUE 12 00 3 PROGRAM TO RECORD DW ST...

Page 12: ...Y SET UP SPECIAL DW MON SAT 6 Turn JOG to set the alarm recording duration you want and turn SHUTTLE to the right When set to MAN 1 alarm recording continues until RST IN terminal is grounded When set...

Page 13: ...OUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END STOP QUASI V SYNC ON VIDEO MODE COLOUR TAPE LENGTH E 180 FIRST TIME SET UP TIME DATE ADJUST TAPE END REWIND QUASI V SYNC ON VIDEO MODE...

Page 14: ...R TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SYNC REC One shot Interval Recording One shot recording allows you to control the number of fields to be recorded when the REC but...

Page 15: ...will turn on by itself when the power comes back on Displaying clearing the power loss list Displaying the power loss list The power failure start time is logged in the VCR s Power Loss List To view t...

Page 16: ...nd present time display appears on screen Note REPEAT REC TIMES are counted when the tape ends during recording except when TAPE END of FIRST TIME SET UP menu is set to STOP memorized even if the VCR...

Page 17: ...ring still picture you can obtain a variety of playback as shown below 1 Turn SHUTTLE to the right or left during still picture The playback speed varies by the angle of SHUTTLE ring When SHUTTLE ring...

Page 18: ...RING or to execute Press STOP to exit 2 Turn SHUTTLE to the right The VCR starts rewinding the tape To quit while rewinding press STOP button To exit the SEARCH FUNCTION menu without rewinding press...

Page 19: ...e fluorescent display during search 2 Turn SHUTTLE to the right TIME DATE SEARCH menu appears 3 Turn JOG to set hour digits of TIME you wish to find and turn SHUTTLE to the right To exit the TIME DATE...

Page 20: ...UDIO VIDEO OUT OUT IN REMOTE IN RESET RST IN REC GND ALM ALM MODE CLK OUT CALL MIC VIDEO OUT AUDIO OUT AUDIO IN VIDEO IN AUDIO IN SENSOR CCTV CAMERA ALM IN GND VIDEO IN VIDEO OUT MONITOR MICROPHONE AM...

Page 21: ...menu setting Remote Recording Connection Connect the VCR with a remote switch as shown below page 13 for the menu setting 1 This connection is necessary in case of Series Recording 2 1 1st VCR RST IN...

Page 22: ...DAY 31 YEAR 2001 TIME 00 00 00 TIME DATE ADJUST DAYLIGHT SAVINGS AUTO MONTH 07 DAY 09 YEAR 2002 TIME 20 25 00 Accurately set the day and present time before timer programming Day Month Year Hour Alar...

Page 23: ...REC OFF CLOG DETECT OFF ONE SHOT FIELD 1 ONE SHOT INTERVAL SHOT REAR TERMINAL CALL OUT WRNG TAPE END CLOCK OUT REC 1 MODE OUT REC REC IN SERIES MAINTENANCE POWER LOSS LIST ALARM LIST ALL MENU INITIALI...

Page 24: ...der of SHOT 10S second 15S 30S 45S 1M minute 2M 3M SHOT RECORDING SET UP ALARM REC MODE 3H ALARM REC DURATION 1M EMERGENCY REC OFF CLOG DETECT ON ONE SHOT FIELD 1 ONE SHOT INTERVAL SHOT TIMER PROGRAM...

Page 25: ...the clock pulse output When JOG is turned the display will be switched in the order of 1 2 3 4 5 10 15 20 25 30 50 60 F field 1 The numbers 1 to 60 indicate the number of frames at 3H or 4H recording...

Page 26: ...e OFF Quasi V sync signal is not inserted Note Some multiplexers may require QUASI V SYNC to be OFF in order to work properly Setting the playback recording colour mode VIDEO MODE AUTO The VCR automat...

Page 27: ...Environmental temperature 5 40 C common with VCR 4 Relative temperature Max 80 common with VCR Remote control switch functions PLAY EJECT SP EP STOP REC PAUSE STILL FR ADV REV FR ADV FF REW REC PLAY M...

Page 28: ...er cord is connected to the outlet for approximately 40 or more hours per week when using it everyday Make sure the power cord is connected to the outlet for approximately 40 or more hours per week wh...

Page 29: ...tons on the front panel Adjust the picture by pressing VERTICAL ADJUST buttons on the front panel The video heads may be clogged Clean the video heads by using the video head cleaning cassette availab...

Page 30: ...VCR automatically remove any particles that may accumulate on the heads during time lapse recording mode If it cannot be entirely removed CLOg flashes on the fluorescent display If so follow the reme...

Page 31: ...ce circuit inside the VCR ALM RST REC IN terminals screw Active When input terminals are short circuited to GND or L level voltage 0 to 1 6 V applied Time for active 0 1 sec or over Non active Open th...

Page 32: ...z 7 kHz 3H mode General Power Source AC 100 230 V 10 50 60 Hz Power Consumption Approx 18 watts Television System CCIR standard 625 lines 50 field PAL type colour system Colour Signal Low frequency co...

Page 33: ...872C271A1 PRINTED IN JAPAN...

Reviews: