background image

Code

20180619-0001

Summary of Contents for HEAT PERFORMER Premium Comfort HP-011/3,5-PC 240

Page 1: ...MMING POOL HEAT PUMP UNIT INSTALLATION INSTRUCTION MANUAL DATA SHEETS Premium Comfort series HP 011 3 5 PC 240 HP 016 5 3 PC 240 HP 021 7 5 PC 240 HP 031 10 4 PC 240 HP 036 13 5 PC 240 HP 041 14 6 PC...

Page 2: ......

Page 3: ...Pumps Plumbing 3 5 Swimming Pool Heat Pumps Electrical Wiring 3 6 Initial Start up of the Unit 4 Usage and Operation 4 1 Function of the controller 4 2 4 3 5 Maintenance and Inspection 5 1 Maintenance...

Page 4: ...rding to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat...

Page 5: ...2 1 The dimensions for Swimming Pool Heat Pump Unit 2 SPECIFICATION 3 All dimensions avalable in data sheets...

Page 6: ...teps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary t...

Page 7: ...r will be re circulated DO NOT place the unit to shrubs which can block air inlet These locations deny the unit of a continuous source of fresh air which reduces it efficiency and may prevent adequate...

Page 8: ...down the fins into the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pu...

Page 9: ...Time Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay...

Page 10: ...NO Symbol Name Function On off Mode Up Press this button can start up or shut down the unit cancel the current operation or back to the upper interface Press this button can switch modes or save param...

Page 11: ...s the inlet water temperature measured value Outlet water It is showed when the AUX display area gives the outlet water temperature measured value Minute It is showed when the main display area gives...

Page 12: ...heat unit For example Press Press Press Press TEMP OUT MODE SET TEMP IN C TEMP OUT MODE SET TEMP OUT MODE SET TEMP OUT MODE SET TEMP OUT MODE SET A TEMP OUT MODE SET TEMP OUT MODE SET MODE SET MODE S...

Page 13: ...hing press to increase value or press to decrease value and press to save setting Press can not save setting parameter and back to main interface Attention If there is no operation for 5s system will...

Page 14: ...our minute Flashing TEMP IN C TEMP OUT MODE SET Flashing Press TEMP IN C TEMP OUT MODE SET Press or TEMP IN C TEMP OUT MODE SET Press to save hour value setting TEMP IN C TEMP OUT MODE SET Press or TE...

Page 15: ...In the off flashing interface press to cancel Attention 1 If there is no operation for 5s system will remember clock setting and back to the main interface 2 By pressing till the off flashing you can...

Page 16: ...SET Press ON Press or OFF TEMP IN C TEMP OUT MODE SET ON OFF TEMP IN C TEMP OUT MODE SET ON OFF Press Press or TEMP IN C TEMP OUT MODE SET ON OFF TEMP IN C TEMP OUT MODE SET Press ON OFF The timer on...

Page 17: ...ing of timer off For example TEMP IN C TEMP OUT MODE SET ON OFF The timer on off has been set Press for 2s TEMP IN C TEMP OUT MODE SET ON OFF ON is flashing TEMP IN C TEMP OUT MODE SET OFF The setting...

Page 18: ...he keyboard will be unlocked NOTES When the unit is in alarming state the key lock can be removed automaticly TEMP IN C TEMP OUT MODE SET Hold on Locked TEMP IN C TEMP OUT MODE SET MODE SET 2 5 Malfun...

Page 19: ...4 USAGE AND OPERATION 17 27 27 27 Meaning Heating inlet target temp Adjustable Adjustable Adjustable 4 3 Parameter table Cooling inlet target temp Auto inlet target temp Remark Default...

Page 20: ...pressure of the refrigerant system should only be serviced by a certified technician Discharge all water in the water pump and water system so that freezing of the water in the pump or water system do...

Page 21: ...rcuit Communication failure between remote wire controller and main board The water inlet temp Sensor is open or short circuit The water outlet temp sensor is open or short circuit The pipe temp senso...

Page 22: ...1 2 3 4 OUT2 Water pump 220 230VAC OUT4 High speed of fan motor 220 230VAC OUT3 OUT1 No Symbol Meaning 4way valve 220 230VAC Compressor of system1 220 230VAC NET GND 12V Wire controller DI01 GND On Of...

Page 23: ...e handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 9...

Page 24: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Page 25: ...Note...

Page 26: ......

Page 27: ...Code 20180619 0001...

Page 28: ...5 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel vo...

Page 29: ...15 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel v...

Page 30: ...15 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel v...

Page 31: ...15 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel...

Page 32: ...r 15 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel...

Page 33: ...15 C 12 C Inlet water 26 C According to IEC EN 60335 1 Premium Comfort series met hoog rendement Deze reeks warmtepompen maakt gebruik van het omgeving vriendelijke medium R32 Zo besparen we 10 koel...

Reviews: