3.2
Mounting
The 32DP can be mounted on a DIN rail (DIN46227) or mounted directly to the mounting surface with screws.
3.2.1
Direct Mounting
The 32DP can be directly mounted with M4 screws.
The 32DP mounting hole pitches are shown below.
→
For the connecting procedure to the extension port of the FX
3G
Series PLC,
refer to FX
3G
PLC Hardware Edition
→
For the connecting procedure to the extension port of the FX
3GC
Series PLC,
refer to FX
3GC
PLC Hardware Edition
→
For the connecting procedure to the extension port of the FX
3U
Series PLC,
refer to FX
3U
PLC Hardware Edition
→
For the connecting procedure to the extension port of the FX
3UC
Series PLC,
refer to FX
3UC
PLC Hardware Edition
→
For the connecting procedure to the extension port of the FX5U PLC,
refer to MELSEC iQ-F FX5U User's Manual (Hardware)
→
For the connecting procedure to the extension port of the FX5UC PLC,
refer to MELSEC iQ-F FX5UC User's Manual (Hardware)
Note
• Mounting screw: M4 screw.
• An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary.
• When connecting the 32DP to an extension unit/block (or special function unit/block), first mount the
extension unit/block (or special function unit/block) to the right side of the PLC.
Direct Mounting
1) Drill screw holes on the mounting surface according to the
diagram above.
2) Align the 32DP (right fig. A) with the holes and tighten with
M4 screws (right fig. B).
3) Connect the 32DP’s extension cable (right fig. C) to the
extension device connector of the main unit.
→
For extension cable connection procedures of the FX
3G
Series PLC, refer to FX
3G
PLC Hardware Edition
→
For extension cable connection procedures of the FX
3GC
Series PLC, refer to FX
3GC
PLC Hardware Edition
→
For extension cable connection procedures of the FX
3U
Series PLC, refer to FX
3U
PLC Hardware Edition
→
For extension cable connection procedures of the FX
3UC
Series PLC, refer to FX
3UC
PLC Hardware Edition
→
For extension cable connection procedures of the FX5U PLC,
refer to MELSEC iQ-F FX5U User's Manual (Hardware)
→
For extension cable connection procedures of the FX5UC PLC,
refer to MELSEC iQ-F FX5UC User's Manual (Hardware)
4
(0.16")
39
(1.54")
80 (3.
15"
)
90 (3.
55"
)
FX
3U
-48M
FX
3U
RUN
POWER
ERROR
BATT
FX
3U
ERROR
RUN
BATT
POWER
0
3
1
2
IN
OUT
6
4
5
21
7
20
24
22
23
26
25
10
11
13
12
16
14
15
17
27
0
3
1
2
6
4
5
21
7
20
24
22
23
26
25
10
11
13
12
16
14
15
17
27
B
A
B
Summary of Contents for FX3U-32DP
Page 1: ...USER S MANUAL FX3U 32DP PROFIBUS DP Interface Block ...
Page 2: ......
Page 6: ... iv ...
Page 73: ......