13 Examples of Wiring for Various Uses
13.5 Input Matrix [MTR Instruction (FNC 52)]
11
Hi
gh
-Speed
Counters
12
O
utput W
iri
ng
13
W
iri
ng for
V
ari
ous
Us
es
14
Te
st R
un,
Mai
nten
ance,
T
roubl
es
hooti
ng
15
IInput/Output
Pow
ered
Exte
nsi
on U
nit
s
16
Input/O
utput
Extens
ion
Bl
ock
s
17
Extension
Power Suppl
y
Un
it
18
Other Extens
ion
Uni
ts an
d
Opti
ons
19
D
isplay M
od
ule
20
Te
rminal
Bl
oc
k
13.5
Input Matrix [MTR Instruction (FNC 52)]
This section gives examples of wiring for capturing the ON/OFF status of 24 switches to M30 to M37, M40 to
M47 and M50 to M57 using MTR instructions.
1. Main Unit
Example of program
Example of wiring
M8000
X020
Y010
M30
K3
MTR
When inputs are used for both sink and source and outputs are the transistor sink type in the used main unit
X020 X021 X022 X023
24V
0V
S/S
Main unit
Y010 Y011 Y012
COM3
X024 X025 X026 X027
M30
M31
M32
M33
M34
M35
M36
M37
M40
M41
M42
M43
M44
M45
M46
M47
X021 X022 X023 X024 X025 X026 X027
M50
M51
M52
M53
M54
M55
M56
M57
X021 X022 X023 X024 X025 X026 X027
0.1A 50V
diode is
necessary.
In case of sink wiring
When inputs are used for both sink and source and outputs are the transistor source type in the used main unit
X020 X021 X022 X023
24V
0V
S/S
Main unit
Y010 Y011 Y012
+V2
X024 X025 X026 X027
M30
M31
M32
M33
M34
M35
M36
M37
M40
M41
M42
M43
M44
M45
M46
M47
X021 X022 X023 X024 X025 X026 X027
M50
M51
M52
M53
M54
M55
M56
M57
X021 X022 X023 X024 X025 X026 X027
0.1A 50V
diode is
necessary.
In case of source wiring
Summary of Contents for FX2-16E series