5
Parameter
5.1
Overview and Setting Ranges
Parameter
20
MITSUBISHI ELECTRIC
Func-
tion
Para-
meter
Meaning
Setting range
Default
Basic
functions
0
Torque boost (manual)
0–30%
6% / 4%
1
Maximum frequency
0–120Hz
120Hz
2
Minimum frequency
0–120Hz
0Hz
3
Base frequency
0–400Hz
50Hz
4
Multi-speed setting (high speed)
0–400Hz
60Hz
5
Multi-speed setting (middle speed)
0–400Hz
30Hz
6
Multi-speed setting (low speed)
0–400Hz
10Hz
7
Acceleration time
0–360s / 0–3600s
5 s / 10s
8
Deceleration time
0–360s / 0–3600s
5 s / 15s
9
Electronic thermal overload relay
0–500A
Rated current
Parameters
for stan-
dard drive
operation
10
DC injection brake operation frequency
0–120Hz
3Hz
11
DC injection brake operation time
0–10s
0.5 s
12
DC injection brake voltage
0–30%
6 %
13
Starting frequency
0–60Hz
0.5Hz
14
Load pattern selection
0–3
0
15
Jog frequency
0–400Hz
5Hz
16
Jog acceleration/deceleration time
0–360s / 0–3600s
0.5s
18
High-speed max. frequency
120–400Hz
120Hz
19
Base frequency voltage
0–1000V/8888/9999
8888
20
Acceleration / deceleration reference frequency
1–400Hz
50Hz
21
Acceleration / deceleration time increments
0 / 1
0
22
Stall prevention operation level
0–200%
150%
23
Stall prevention operation at double speed
0–200% / 9999
9999
24
Multi-speed setting (speed 4)
0–400Hz / 9999
9999
25
Multi-speed setting (speed 5)
0–400Hz / 9999
9999
26
Multi-speed setting (speed 6)
0–400Hz / 9999
9999
27
Multi-speed setting (speed 7)
0–400Hz / 9999
9999
29
Acceleration / deceleration pattern
0 / 1 / 2
0
30
Regenerative function selection
0 / 1
0
31
Frequency jump 1A
0–400Hz / 9999
9999
32
Frequency jump 1B
0–400Hz / 9999
9999
33
Frequency jump 2A
0–400Hz / 9999
9999
34
Frequency jump 2B
0–400Hz / 9999
9999
35
Frequency jump 3A
0–400Hz / 9999
9999
36
Frequency jump 3B
0–400Hz / 9999
9999
37
Speed display
0 / 0.1–9998
0
38
Frequency at 5V (10V) input voltage
1–400Hz
50Hz
39
Frequency at 20mA input current
1–400Hz
50Hz
Setting of
control out-
puts
41
Up-to-frequency sensitivity
0–100%
10%
42
Output frequency detection
0–400Hz
6Hz
43
Output frequency detection for reverse rotation
0–400Hz / 9999
9999