2.Performance Specifications

The performance specifications for Network Modules are indicated as follows.

Topic

AJ71QLP21(S)

AJ71QLR21

AJ71QBR11

X/Y

8192 points

B

8192 points

Maximum link points
per 1 network

W

8192 points

When
constructin
g a PC
network

B+Y

8

+(2 W)

+

(2

×

W)

2000 bytes

Maximum
link points
per 1
station

When
constructin
g a remote
I/O network

#

Remote master station

remote I/O station

B+Y

8

+(2 W)

+

(2

×

W)

1600 bytes

#

Remote I/O station

remote master station

B+X

8

+(2 W)

+

(2

×

W)

1600 bytes

#

Remote master station

remote sub master station

Remote sub master station

remote master station

Y+B

8

+(2 W)

+

(2

×

W)

2000 bytes

Communication speed

10Mbps (20Mbps: Multiplex transmission)

10Mbps

Communication method Token ring mode

Token pass mode

Synchronous mode

Frame synchronous mode

Transmission circuit
format

Double loop (Optical fiber
cable)

Double

loop

(Coaxial cable)

Single pass (Coaxial cable)

30km

3C-2V

3C-2V

5C-2V

19.2km

(inter

station 300m)

300m
(inter station
300m)

500m
(inter station
500m)

5C-2V

General extension
distance
(Inter station distance)
*1

[

SI cable H type inter station 300m
SI cable L type inter station 500m
QSI cable inter station 1km

]

30km

(inter

station 500m)

Repeater module (A6BR10,
A6BR10-DC) Maximum
expansion is 2.5km

Maximum number of
networks

239

Maximum number of
groups

9 (Only in a PC network)

When
constructin
g a PC
network

64 stations
(Control station: 1 Normal stations: 63)

32 stations
(Control station: 1
Normal stations: 31)

Number of
connection
Stations in
1 network

When
constructin
g a remote
I/O network

65 stations
Remote master station: 1
Remote I/O stations: 64

33 stations
Remote master station:1
Remote I/O stations:32

 

Summary of Contents for AJ71QBR11

Page 1: ...r buying the Mitsubishi general purpose programmable logic controller MELSEC QnA Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the produ...

Page 2: ...rly Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so...

Page 3: ...not tightened to the specified torque it the module may fall out short circuit or malfunction If a terminal screw is tightened excessively exceeding the specified torque the module may fall out short...

Page 4: ...ing This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems...

Page 5: ...ng of Each Part 5 5 Wiring 10 5 1 Precautions for Laying Optical Fiber Cables 11 5 2 Precautions when Installing the Coaxial Cables 13 5 2 1 For the Coaxial Loop Type 13 5 2 2 For the Coaxial Bus Type...

Page 6: ...ence Manual IB 66690 13JF78 Correspondence to EMC DIRECTIVE For instructions to make the PLC compatible with EMC standards refer to EMC AND LOW VOLTAGE DIRECTIVE in PLC CPU User s Manual Hardware When...

Page 7: ...sion base I O slot 2 Please verify the existence of the following parts after opening the package a In the case of AJ71QLP21 Product name Quantity AJ71QLP21 Network module 1 b In the case of AJ71QLP21...

Page 8: ...en pass mode Synchronous mode Frame synchronous mode Transmission circuit format Double loop Optical fiber cable Double loop Coaxial cable Single pass Coaxial cable 30km 3C 2V 3C 2V 5C 2V 19 2km inter...

Page 9: ...able SI 200 220 SI 200 250 QSI 185 230 Arranged by user 2 3C 2V 5C 2V Equivalent goods Integration cable 2 core optical connettor plug DL 72ME For SI 200 250 CA7003 CA7005 For SI 200 220 and QSI 185 2...

Page 10: ...holes Not installing the module correctly or tightening the screws to the terminal base could result in erroneous operation damage or pieces of the product falling 3 1 Cable length restrictions betwee...

Page 11: ...RC OVER AB IF TIME DATA UNDER LOOP SD RD POWER MNG S MNG D LINK T PASS CPUR W CRC OVER AB IF TIME DATA UNDER LOOP SD RD F LO O P R LO O P 10 1 100 E R R O R E R R O R NETWORK NO X100 X10 X1 GROUP NO S...

Page 12: ...iving communication which is 1 above the regulations and or when the length of the receiving data is short lamp is lit Primary causes The timing of a station in parallel condition sending data to the...

Page 13: ...8 7 6 1 GR NO Network number setting factory setting at time of shipping 1 Setting range 1 to 239 Network number Other than 1 to 239 Setting error SW E LED lamp is lit Becomes off line condition Stati...

Page 14: ...f back to back test By the unit simplex check the hardware including the sending and receiving communication circuit of the transmission system 9 Hardware test Check the internal hardware of the netwo...

Page 15: ...hen preventing loop pack by turning OFF the power source of the PLC CPU supply an external power source 24V 24G FG 1 EXT PW LED light by the power supply for the network generated with an external pow...

Page 16: ...ightened to the specified torque it the module may fall out short circuit or malfunction If a terminal screw is tightened excessively exceeding the specified torque the module may fall out short circu...

Page 17: ...1000 3281 ft 2 When connecting an optical fiber cable the following restrictions on the bending radius must be observed Cable type Allowable bending radius Connector A mm in Type 2 8mm area mm in CA90...

Page 18: ...hands dirt or dust should adhere to the core the transmission loss will increase causing a malfunction in the data link 5 When attaching or detaching the optical fiber cable to from the module hold th...

Page 19: ...1 38 r Module front A 3 The Coaxial cable is wired in the following manner There is no problem even if not wiring in order of the station number There is no problem even if station how many become con...

Page 20: ...mber of stations connected Cable length between stations Total extension distance 2 to 9 stations 1 to 300 m 3C 2V 3 28 to 984 3 ft 1 to 500 m 5C 2V 3 28 to 1640 5 ft 10 to 33 stations 1 to 5 m 3C 2V...

Page 21: ...nd control cables 7 Consider wiring using double shielded coaxial cable in places that are subject to large amounts of noise Double shielded coaxial cable Mitsubishi Cable 5C 2V CCY Grounding 8 Do not...

Page 22: ...er Gasket Plug shell Clamp Contact Parts comprising the BNC connector Outer sheath Insulation material External conductor Internal conductor Structure of the coaxial cable 2 How to connect the BNC con...

Page 23: ...n 6 mm 0 24 in d Solder the contact to the internal conductor Solder here e Insert the connector assembly in d into the plug shell and screw the nut into the plug shell Important Note the following pr...

Page 24: ...B LWS I ZE 2 4 6 8K O FF O N O N SW 1 2 3 4 5 6 7 8 AJ71QLP21S RUN PC REMOTE DUAL SW E M S E PRM E CRC OVER AB IF TIME DATA UNDER LOOP SD RD POWER MNG S MNG D LINK T PASS EX POWER CPUR W CRC OVER AB I...

Page 25: ...4 6 8K OFF ON ON SW 1 2 3 4 5 6 7 8 AJ71QLR11 RUN PC REMOTE DUAL SW E M S E PRM E CRC OVER AB IF TIME DATA UNDER LOOP SD RD POWER MNG S MNG D LINK T PASS CPUR W CRC OVER AB IF TIME DATA UNDER LOOP SD...

Page 26: ...32 64 LB LW SIZE 2 4 6 8K OFF ON ON SW 1 2 3 4 5 6 7 8 AJ71QBR11 RUN PC REMOTE SW E M S E PRM E CRC OVER AB IF TIME DATA UNDER SD RD POWER MNG S MNG D LINK T PASS CPUR W 10 1 100 E R R O R 7 0 28 50 1...

Page 27: ...0880 Ratingen GERMANY Tel 49 2102 486 0 South Africa MSA Manufacturing Pty Ltd P O Box 39733 Bramley 201 8 Johannesburg South Africa Tel 27 11 444 8080 India Messung Systems Put Ltd Electronic Sadan N...

Reviews: