15
RC-HY20/40 – at your service
Menu 1.3 - temperature scheduling
,QWKHPHQXVFKHGXOLQJLQGRRUFOLPDWHKHDWLQJFRROLQJLV
scheduled for each weekday.
You can also schedule a longer period during a selected period
YDFDWLRQLQPHQX
scheduling
1.3
cooling
off
heating
off
Menu 1.3.1 - heating
Increases or decreases in the accommodation temperature can
be scheduled here for up to three time periods per day. One
step is usually enough to change the room temperature by one
GHJUHHEXWLQVRPHFDVHVVHYHUDOVWHSVPD\EHUHTXLUHGIRUWKH
accommodation temperature.
,IDURRPVHQVRULVLQVWDOOHGDQGDFWLYDWHGWKHGHVLUHGURRP
WHPSHUDWXUH&LVVHWGXULQJWKHWLPHSHULRGV
SCHEDULING HEATING
1.3.1
activated
schedule 2
system
schedule 3
schedule 1
all
mon
tues
wed
thur
fri
sat
sun
21:30
-
06:00
20.5°
Time period
Adjusting
Day
Activated
Schedule
System
Conflict
Schedule:
The schedule to be changed is selected here.
Activated:
6FKHGXOLQJIRUWKHVHOHFWHGSHULRGLVDFWLYDWHG
KHUH6HWWLPHVDUHQRWD൵HFWHGDWGHDFWLYDWLRQ
System (RC-HY40 only):
Which climate system the
VFKHGXOH LV IRU LV VHOHFWHG KHUH 7KLV DOWHUQDWLYH LV RQO\
displayed if more than one climate system is present.
Day:
Select which day or days of the week the schedule is to
DSSO\WRKHUH7RUHPRYHWKHVFKHGXOLQJIRUDSDUWLFXODUGD\
the time for that day must be reset by setting the start time to
the same as the stop time. If the line "all" is used, all days in
the period are set for these times.
7KHQXPEHURIVWHSVWKHYDOXHKDVWREHFKDQJHGWRDFKLHYHD
degree change of the indoor temperature depends on the
heating installation. One step is usually enough but in some
FDVHVVHYHUDOVWHSVPD\EHUHTXLUHG
7KHQHZYDOXHLVVKRZQRQWKHULJKWKDQGVLGHRIWKHV\PERO
in the display.
CAUTION
An increase in the room temperature can be slowed by the
thermostats for the radiators or under floor heating.
Therefore, open the thermostats fully, except in those rooms
where a cooler temperature is required, e.g. bedrooms.
TIP
Wait 24 hours before making a new setting, so that the
room temperature has time to stabilise.
If it is cold outside temperature and the room temperature is
too low, increase the curve slope in menu 1.9.1.1 by one
increment.
If it is cold outside temperature and the room temperature is
too high, reduce the curve slope in menu 1.9.1.1 by one
increment.
If it is warm outside temperature and the room temperature
is too low, increase the value in menu 1.1.1 by one increment.
If it is warm outside temperature and the room temperature
is too high, reduce the value in menu 1.1.1 by one increment.