background image

2

1

2

1

5 4

1

2

3

6

7

7

5 4 3 2 1

CN2

6

1

2

3

4

5

2 1

10

9

6

5

2

1

3

2

1

2

3

2

1

6 3 2 1 6 5 4 3

1

2

6 3

7

3

2

1

5

4

3

2

1

4 3 2 1

6

V

U

U

W

WHT

1

2

3

6

C5

RED

RED

10

9

6

5

2

1

7 3

6 2 1

4 5

3

2

1

2 3

1

1 2

3

1

1 2

1 3

2

1

1

2

CN40

CN3D

(WHT)

(WHT)

C2

C1

ORN

ORN

RED

RED

WHT

BLU

WHT

MF1

MF2

CN41

<MULTI CONTROLLER BOARD>

TH1

26C

SLEV

TH5

63HS

TH6

TH2

SV1

52C

21S4

TB3

ON

OFF

CH

SW2

X3

X1

X2

TO INDOOR UNIT
CONNECTING WIRES
DC 30V (Non-polar)

 FUSE2

 (6A)

ORN

ORN

BRN

YL

W

(WHT)  (GRN)

(GRN) (WHT)

RED

RED

WHT

BLK

BLK

WHT

BLU

FOR CENTRALIZED
CONTROL
DC 30V (Non-polar)

2

RED

6

3

1

1

2

F.C

1 2 3 4

CNCT

CN51

1

2

AC,CT

(YLW)

(YLW)

CNS2

(RED)

CNS1

(WHT)

(WHT)

(WHT)

(WHT)

(WHT)

(BLK)

THHS

ON

OFF

SW5

 FUSE1 (2A)

WHT

RED

YL

W

6

4

5

1 2 3 4 5 6 7 8 910

8

7

6

5

4

3

2

1

6

CN4

CN3

CN2

CN1

CN3

CN1

CN5

CN6

CH

CNA

52C

21S4

SV1

MF1

MF2

CND

<POWER SUPPLY BOARD>

SWU3

(3rd digit) (2nd digit)

SWU2

(1st digit)

SWU1

LD1

(YLW)

(WHT)

(YLW)

(RED)

(WHT)

(YLW)

(RED)

(WHT)

(WHT)

(YLW)

26C

(BLK)

M1

M2

S

M1

1 3

RED

WHT

3 1

3 1

3 1

3 1

3 1

3 1

1 3

0 1

2

3

45

6

7

8

9

9

8

7

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

N(-)

P(+)

P(+)

N(-)

V

W

U

V

W

RED

WHT

BLU

6

3

7

CN4

CN6

CN5

<GATE AMP BOARD>

AC.CT

<IPM>

(YLW)

(WHT)

(WHT)

CNCT

RED

FUSE(30A)

3

4

1

NF1

2

L2

TB1

L

1

TB7

POWER SUPPLY

BRN

RED

WHT

RED

WHT

GRN/YLW

M2

S

52C

RED

RED

R1

D1

+

C3

ZNR

DS

R2

DCL

RED

RED

WHT

WHT

RED

63HS

TH6 TH5

SLEV

TH2 TH1

THHS

MC

1 2

3

2

1

SW3

ON

OFF

SW4

4

SW1

OFF

ON

3 4 5 6 7 8

2

1

PUMY-71VM
Only

Single-phase  220-240V 50Hz

Single-phase  2

08-230

V 60Hz

NAME

SYMBOL

NAME

NAME

SYMBOL

SYMBOL

AC,CT
CH
CNA
CND
CNS1
CNS2
CN1
CN2
CN3
CN4
CN5
CN6
CN40
CN41
CN51
CN3D
CNCT
C1,2
C3
C5
DS
D1
DCL

F.C
FUSE1
FUSE2
FUSE
IPM
LD1

MC
MF1,2
NF1
R1
R2
SLEV
SV1
SW1
SW2
SW3
SW4
SW5
SWU1
SWU2
SWU3
TB1

TB3
TB7

THHS

TH1
TH2

TH5

TH6
X1

X2
X3
ZNR
21S4
26C
52C

63HS

Current detection
Crankcase heater
Connector <Power supply>
Connector <DC Power supply>
Connector <Multi system>
Connector <Centralized  control>
Connector <Controller  drive  control>
Connector <Power  sync  signal, protection>
Connector <Power supply 30V, 12V, 5V>
Connector <Inverter signal 5V>
Connector <IPM power supply>
Connector <IPM  power  supply, trouble  output>
Connector <Centralized  control power  supply>

  

Connector <For storing  jumper  connector>
Connector <Compressor drive signal output>
Connector <Demand signal, silent mode input>
Connector <Current detection>
Fan motor capacitor
Capacitor <Smoothing>
Capacitor <Power factor improvement>
Diode stack
Diode <Power  factor improvement>
Reactor

Fan control
Fuse(2A)
Fuse(6A)
Fuse(30A)
Intelligent power module
Digital indication LED
<Operation inspection indication>
Compressor
Fan motor (Inner thermostat)
Noise filter
Resistor <Rush current protect>
Resistor <Discharge>
Expansion valve
Solenoid valve <Hot gas bypass>
Switch <Display selection selfdiagnosis>
Switch <Function selection>
Switch <Test run>
Switch <Model selection>
Switch <Function selection>
Switch <Unit address selection,1st digit>
Switch <Unit address selection,2nd digit>
Switch <Unit address selection,3rd digit>
Terminal block <Power supply>

Terminal block <Transmission>
Terminal block
<Transmission> (Centralized control)
Thermistor
<IPM Radiator panel temperatuer detection>
Thermistor <Discharge temperatuer detection>
Thermistor
<Low pressure saturated temperatuer detection>
Thermistor
 <Pipe temperatuer detection, judging defrost>
Thermistor <Outdoor temperatuer detection>
Relay
<Crankcase heater, magnetic contactor>
Relay <4-way valve>
Relay <Solenoid valve>
Varistor
4-Way valve
Thermal switch <Compressor>
Magnetic contactor
<Inverter main circuit>
High pressure sensor
<Discharge pressure detection>

       1.Refer to the wiring boards of the indoor units for details on wiring of each indoor unit.
       2.The transmission line is two-wire type and has no polarity.
       3.Mark       shows the terminal board,mark       the connector .Symbols in parentheses () show the colors of connectors.
       4.Self-diagnosis function

         The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch(SW1) and LD1(LED indication) 

         found on the multi-controller of the outdoor unit.
         LED indication : Set all contacts of SW1 to OFF.

1

3

PUMY

1

1

Outdoor units / Y series / PUMY-71·125VM

5. Electrical Wiring Diagram

PUMY-71VM

Summary of Contents for Y Series

Page 1: ...Correction by refrigerant piping length 2 4 Correction at frosting and defrosting 2 5 Operation limit 3 Sound Levels 4 External Dimensions 5 Electrical Wiring Diagram 6 Refrigerant Circuit Diagram And Thermal Sensor PUMY 71VM PUMY 125VM 2 4 4 6 8 9 9 10 11 13 15 1 PUMY 1 1 Outdoor units Y series PUMY 71 125VM ...

Page 2: ...ntity Airflow rate Motor output Type Motor output Crankcase heater Refrigerant Lubricant External finish External dimension mm Protection devices High pressure protection Compressor Fan Inverter Refrigerant piping diameter Liquid Gas Indoor unit Total capacity Model Quantity Noise level Net weight Operating temperature range dB A kg 2 Works not included Installation foundation work electrical conn...

Page 3: ...antity Airflow rate Motor output Type Motor output Crankcase heater Refrigerant Lubricant External finish External dimension mm Protection devices High pressure protection Compressor Fan Inverter Refrigerant piping diameter Liquid Gas Indoor unit Total capacity Model Quantity Noise level Net weight Operating temperature range dB A kg 2 Works not included Installation foundation work electrical con...

Page 4: ... 63 208 230V 17 5 16 7 16 0 18 1 PUMY 125VM 14 0 6 57 6 43 34 9 33 5 32 2 33 6 Cooling The Ratio of Cooling Capacity 0 80 0 90 1 00 1 10 1 20 10 0 10 20 30 40 50 Outdoor Temperature CDB Ratio 16 CWB 18 CWB 20 CWB 22 CWB Indoor Temperature CWB The Ratio of Cooling Power Input 0 40 0 60 0 80 1 00 1 20 1 40 10 0 10 20 30 40 50 Outdoor Temperature CDB Ratio 22 CWB 16 CWB 18 CWB 20 CWB 4 PUMY 2 1 Corre...

Page 5: ...17 4 16 0 17 6 The Ratio of Heating Capacity 0 60 0 70 0 80 0 90 1 00 1 10 1 20 1 30 15 10 5 0 5 10 15 20 Outdoor Temperature CWB Ratio 15 CDB 20 CDB 25 CDB Indoor Temperature CDB The Ratio of Heating Power Input 0 60 0 70 0 80 0 90 1 00 1 10 1 20 15 10 5 0 5 10 15 20 Outdoor Temperature CWB Ratio 15 CDB 20 CDB 25 CDB Indoor Temperature CDB PUMY 71VM 16 0 6 10 6 03 32 6 31 2 29 9 31 5 PUMY 125VM H...

Page 6: ... 80 90 100 Heating Cooling PUMY 71VM Heating Cooling Cooling Heating 220V 50Hz 220V 60Hz 220V 50Hz 220V 60Hz 220V 50Hz 220V 60Hz 220V 50Hz 220V 60Hz 3 00 3 50 4 00 2 00 2 50 10 0 12 0 14 0 16 0 18 0 20 0 Input kW Current A Total capacity of indoor units Total capacity of indoor units 2 Input 3 Current 6 PUMY 2 2 Correction by total indoor ...

Page 7: ...80 Heating Cooling PUMY 125VM Heating Cooling Cooling Heating 220V 50Hz 220V 60Hz 220V 50Hz 220V 60Hz 50Hz 60Hz 50Hz 60Hz 4 00 5 00 6 00 7 00 2 00 3 00 14 0 16 0 18 0 20 0 22 0 24 0 26 0 32 0 34 0 36 0 28 0 30 0 Input kW Current A Total capacity of indoor units Total capacity of indoor units 2 Input 3 Current 7 PUMY 1 1 Outdoor units Y series PUMY 71 125VM ...

Page 8: ... of indoor unit PUMY 71VM PUMY 71VM PUMY 71VM Equivalent length Actual piping length to the farthest indoor unit 0 3 number of bent on the piping m PUMY 125VM Equivalent length Actual piping length to the farthest indoor unit 0 35 number of bent on the piping m How to obtain piping equivalent length 35 71 Heating capacity correction factor 1 0 0 9 0 8 0 7 10 0 20 30 40 50 60 Piping equivalent leng...

Page 9: ...orrection factor in the table below represents the heating capacity Outdoor inlet air temp CWB Correction factor 6 4 2 0 2 4 6 8 10 1 0 0 98 0 89 0 88 0 89 0 9 0 95 0 95 0 95 Correction factor table 2 5 Operation limit Cooling Heating Indoor temperature CWB 5 0 5 10 15 20 25 30 35 40 45 50 10 15 20 25 30 Indoor temperature CDB 15 10 5 0 5 10 15 20 10 15 20 25 30 Outdoor temperature CDB Outdoor tem...

Page 10: ...asurement condition Measurement condition 1m 1m A B NC60 NC50 NC40 NC30 NC20 Approximate minimum audible limit on continuous noise 70 60 50 40 30 20 63 125 250 500 1000 2000 4000 8000 10 OCTAVE BAND CENTER FREQUENCIES Hz NC60 NC50 NC40 NC30 NC20 70 60 50 40 30 20 63 125 250 500 1000 2000 4000 8000 10 OCTAVE BAND CENTER FREQUENCIES Hz Approximate minimum audible limit on continuous noise 1m 1m A B ...

Page 11: ...on Knock out hole for right piping Gos refrigerant pipe connection ø 15 88 5 8F Handing for moving Service panel Liquid refrigerant pipe connection ø 9 52 3 8F Knock out holes for power line 2 ø 27 Knock out holes fo power line 2 ø 27 Optional parts base branching pipe installation hole Bottom piping hole Piping cover shaped notched holes standard bolt M10 Drain hole 3 ø 33 hole standard bolt M10 ...

Page 12: ...g Knock out holes for power line 2 ø 27 Gos refrigerant pipe connection ø 19 05 3 4F Liquid refrigerant pipe connection ø 9 52 3 8F Knock out hole for right piping Bottom piping hole shaped dotched holes standard bolt M10 Drain hole 3 ø 33 hole Optional parts base branching pipe installation hole Knock out holes for power line 2 ø 29 1 Indicates the dimensions of the cutoff valve connector 2 Make ...

Page 13: ...upply 30V 12V 5V Connector Inverter signal 5V Connector IPM power supply Connector IPM power supply trouble output Connector Centralized control power supply Connector For storing jumper connector Connector Compressor drive signal output Connector Demand signal silent mode input Connector Current detection Fan motor capacitor Capacitor Smoothing Capacitor Power factor improvement Diode stack Diode...

Page 14: ... control Connector Power sync signal protection Connector Power supply 30V 12V 5V Connector Inverter signal 5V Connector IPM Power supply Connector IPM Power supply trouble output Connector Centralized control power supply Connector For storing jumper connector Connector Compressor drive signal output Connector Demand signal silent mode input Fan motor capacitor Capacitor Power factor improvement ...

Page 15: ... exchanger Linear expansion valve LEV Thermistor TH2 Saturation temperature of suction pressure Capillary tube 2 Capillary tube 3 Oil separator Check valve low pressure Thermistor THHS Radiator panel temperature sensor Thermistor TH6 outdoor air temperature sensor 4 way valve High pressure sensor discharge pressure sensor 63HS Capillary tube 1 Check valve High prssure Electromag netic valve SV1 Th...

Page 16: ...16 PUMY ...