![Mitsubishi Electric WSH-ZM35I BEDRAAD SET Service Manual Download Page 15](http://html.mh-extra.com/html/mitsubishi-electric/wsh-zm35i-bedraad-set/wsh-zm35i-bedraad-set_service-manual_1810102015.webp)
15
OCH751
5-4. STANDARD OPERATION DATA
The unit of pressure has been changed to MPaG based on international SI system.
The conversion factor is: 1(MPaG)=10.2(kgf/cm²)
Representative matching
PLA-ZM35EA2(-ET/-ER)
PLA-ZM50EA2(-ET/-ER)
Mode
Cooling
Heating
Cooling
Heating
Total
Capacity
W
3,600
4,100
5,000
6,000
Input
kW
0.71
0.82
1.11
1.36
Electrical circuit
Indoor unit
PLA-ZM35EA2(-ET/-ER)
PLA-ZM50EA2(-ET/-ER)
Phase, Hz
1, 50
1, 50
Voltage
V
230
230
Current
A
0.21
0.19
0.22
0.20
Outdoor unit
PUZ-ZM35VKA2(-ET/-ER)
PUZ-ZM50VKA2(-ET/-ER)
Phase, Hz
1, 50
1, 50
Voltage
V
230
230
Current
A
3.17
3.53
4.80
5.85
Refrigerant circuit
Discharge pressure
MPaG
2.51
2.04
2.68
2.44
Suction pressure
MPaG
1.12
0.74
1.02
0.69
Discharge temperature
°C
65
72
76
87
Condensing temperature
°C
42
34
44
41
Suction temperature
°C
15
9
13
6
Ref. pipe length
m
5
5
5
5
Indoor
s
ide Intake air temperature
D.B.
°C
27
20
27
20
W.B.
°C
19
15
19
15
Discharge air temperature
D.B.
°C
17.5
30.8
15.5
35.5
Outdoor
side Intake air temperature
D.B.
°C
35
7
35
7
W.B.
°C
24
6
24
6
SHF
0.97
—
0.81
—
BF
0.18
—
0.17
—