Page 24
MODELS: WD-60735 / WD-60C8 / WD-65735 / WD-65736 / WD-65835 / WD-65C8 / WD-73735 /
WD-73736 / WD-73835 / WD-73C8
3. Error Code Operational Check
Note:
The TV must be in “Shut Down” and not have been switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to “12” No Error.
Pressing the front panel “INPUT” and “MENU” buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The “TIMER LED” flashes denoting a two digit Error Code, or indicating no
problem has occurred since the last Initialization.
Note:
The front panel buttons must be used, NOT those on the Remote Control.
•
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
•
The flashing then pauses for approximately 1/2 second.
•
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
•
The Error Code is repeated a total of 5 times.
Example: If the Error Code is “23”, the LED will flash two times, pause, and then flash three times.
LED Indicator Diagnostics
The front panel LEDs provide an indication of the set’s operation, and the possible cause of a malfunction. There are three
front panel LEDs, “Power”, “Status” and “Lamp”. The LED display shows the current status or indicates a possible
malfunction.
Pow er/Tim e r
LED
Sta tus LED
La m p LED
Condition
Off
Yellow
Off
Tem perature high - room too hot.
Tem perature sensor is disconnected
Off
Off
Blinking
Yellow
Lam p cover open.
Lam p Failure - Lamp failed to turn On.
Off
Off
Red*
Lamp is broken
Lamp turns Off during P-ON
Off
Blinking Red
Off
Fan Stopped
Circuit failure (short)
Disconnected DVI cable, chassis to engine
Off
Red
Off
No LAMP-EN signal from Engine to turn
the lamp On.
Ballast UART com munication problem.
* A red Lamp LED only occurs after 2 attempts to light the lamp.
Each attempt (pressing POW ER) must be at least 65 seconds apart.
During each attem pt ballast striking may be audible.
ABNORMAL LE D INDICATION S
Pow e r/Tim e r
LED
Sta tus LED
La m p LED
Condition
Off
Off
Off
Off (Standby )
Fast Blink
Green
Off
Off
Initialization (40 - 60 seconds ) (AC Off)
Off
Off
Green Blink
Lam p cooling (90 s econds after P TV Off)
(Fan is still work ing)
Green
Off
Off
Power On
Slow B linking
Green
Off
Off
Power On Tim er is s et
NORMAL LED INDICATIONS
Summary of Contents for WD-60735
Page 2: ......