4 Basic Adjustment
For M6 family, test mode is not directly possible from the mobile, indeed relevant software is available
on PC only.
Thanks to the new generation of MT Tools (MT Tools 2000), we can either repair Level 2 or Level 3.
4.1 Equipment installation
The test mode is used to control or adjust mobile parameters.
You must have the following requirements :
•
Radio-communication tester
•
M5 RF cable
•
M5 Interface cable
•
M4 / M5 Interface Box
•
Serial Cable
•
Computer under Windows 95 minimum (PII 350 MHz 64 Mb recommended)
•
An ampermeter can be installed between the external supply and the interface box to check the
mobile consumption.
NSMA ADAPTATOR MALE
(F5CN000410)
M5 RF CABLE SMA L100
(F5CN000310)
Mobile without battery
RADIOCOMMUNICATION TESTER
ITSU
External supply
4.5V
GPIB Connection for Autotest only
(not requested for test mode)
Serial Cable
FT7Y002110
M4 /M5 Interface Box
FT7Y009410
M5 Interface Cable
F5CN000110
CORDON M5 RF SMA M/SMA M
(F5CN000210)