12
3. Operation
F1
F2
F3
F4
Direct/Indirect setting
: Direct
: Indirect
: Indirect
: Direct
Select:
Outlet
Angle
■
i-See button (Wireless remote controller)
1
Each time
is pressed during operation, the setting changes in
the following order: OFF → Direct → Indirect.
Display
Setting
OFF
Direct
Indirect
When the setting is changed from OFF to Direct or Indirect, the vane setting
changes to "Auto". This setting is applied collectively to all of the vanes.
3
When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT]
button to save the settings.
* In order to enable this function,
the airflow direction must be set
to “Auto”.
3.6.3 Energy saving option
F1
F2
F3
F4
Energy saving option
Cursor
Setting display:
No occupancy energy save
Room occupancy energy save
No occupancy Auto-OFF
1
Select the desired menu with the
[F1] or [F2] button.
No occupancy energy save
If there are no persons in the room
for 60 minutes or more, energy-
saving operation equal to 2 °C
(4 °F) is performed.
Room occupancy energy save
If the occupancy rate decreases
to approximately 30% of the maxi-
mum occupancy rate, energy-
saving operation equal to 1 °C
(2 °F) is performed.
No occupancy Auto-OFF
If there are no persons in the
room for the set amount of time
(60–180 minutes), the operation
is automatically stopped.
2
When No occupancy energy save
or Room occupancy energy save
is selected
Select the setting with the [F4]
button.
OFF
→
Cooling only
→
Heating
only
→
Cooling/Heating
→ OFF…
After changing the setting, press
the [SELECT] button to save the
setting.
OFF: The function is disabled.
Cooling only: The function is ena-
bled only during cooling mode.
Heating only: The function is ena-
bled only during heating mode.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
3
When No occupancy Auto-OFF is
selected
Set the time with the [F3] or [F4]
button.
---: The setting is disabled (the op-
eration will not stop automatically).
60–180: The time can be set in
10-minute increments.
4
The message at left will appear
if the operation was stopped
automatically by the No occupancy
Auto-OFF setting.
F1
F2
F3
F4
Energy saving option
Select:
No occupancy energy save
Cooling/Heating
F1
F2
F3
F4
Energy saving option
Select:
Room occupancy energy save
Cooling/Heating
F1
F2
F3
F4
Energy saving option
Select:
Time
No occupancy Auto-OFF
120
min.
F1
F2
F3
F4
18:47 Thu
Shut down by
No Occupancy Auto-OFF
31/Dec AM12:59
BH79A445H01_EN.indd 12
2018/08/07 9:06:06